Wheel For Cart Style Stations
112699 Robinair Oil Injector O-Ring
114692 Robinair Oil Bottle Cap for Oil Inject / Drain bottle, for 8 - 12 ounce oil injector bottles. Durable plastic resists oils and dyes and most chemicals. Easily cleaned for long life. Don't forget extra bottles (115642) for storing different oil types.
114693 Robinair Oil Bottle Cap (Less Liner With Holes) For Oil Injectors
These gaskets fit 1/4" flare and 1/2 ACME standard hose fittings. If you are doing maintenance on you unit it's a good idea to replace these as well as they become crushed over time resulting in poor flow or restriction due to swelling. These are standard for some other vendors hoses as well.
12oz. Graduated Oil Drain - Oil Injector Bottle. 12oz Capacity in 1/2oz graduations and 360 Milliliters in 10 Milliliter graduations, for dispensing oil via an injector or for measuring oil removed during refrigerant recovery process. Durable plastic resists oils and dyes and most chemicals. Easily cleaned for long life. Don forget extra caps (114692) for storing different oil types.
12oz. Graduated Oil Injector Bottle. 12oz Capacity in 1/2oz graduations and 360 Milliliters in 10 Milliliter graduations. For storing alternative oils for injection & for dispensing oil via an injector or for measuring oil removed during refrigerant recovery process. Durable plastic resists oils and dyes and most chemicals. Easily cleaned for long life. Includes cap & Level O-ring.
Robinair’s "High Vacuum Pump Oil" is engineered to maintain maximum viscosity at high running temperatures and to improve cold weather starts. Laboratory tests prove that Robinair "High Vacuum Pump Oil" is more thermally stable in comparison to other leading brands, which means it resists breaking down due to heat for a longer period of time.
Recycling Filter Drier Core Features low pressure drop with maximum moisture and acid retention. Hermetically sealed cans prevent exposure to dirt and moisture.
8oz. Graduated Oil Drain - Oil Injector Bottle. 8oz Capacity in 1/2oz graduations and 240 Milliliters in 10 Milliliter graduations, for dispensing oil via an injector or for measuring oil removed during refrigernt recovery process.
Designed to protect recevery systems from debris and deposits that would normally harm your unit. Large filter capacity provides long life. All steel construction with enamel finish resists corrosion and rusting.
50lb. R-12 / Universal Gas Refillable Refrigerant Tank. Red Vapor Blue Liquid Ported Valve. 50 lb. capacity refrigerant tank for R-12, R-22, R-502 (universal) with 1/4" Flare fittings
Designed to protect recovery systems from debris and deposits that would normally harm your unit. Large filter capacity provides long life. All steel construction with enamel finish resists corrosion and rusting. 1/4" inlet fitting and 3/8" outlet fittings are standard.
The 17800C is ideal for refrigerated trailers, buses, RVs, and other vehicles that use more than one refrigerant and have system charges greater than 6 pounds. The 17800B Recovers, Recycles, Evacuates, and Recharges R-12, R-134a, R-22, R-502, R-404, MP and HP Blends and many more! all in one fast, continuous operation through one hook-up.
19056 Robinair Heavy Duty Refrigerant Tank Strap With Buckle
19205 36" Yellow Tank Hose W / Depressors. Enviro-Guard Hoses for Automotive R-134A. Enviro-Guard Hoses are constructed of special barrier material which prevent virtually any permeation of refrigerant, yet remains flexible.
These gaskets fit 1/4" flare and 1/2 ACME standard fittings. If you are doing maintenance on you unit it's a good idea to replace these as well as they become smashed over time resulting in poor flow.
Enviro-Guard Hoses are constructed of special barrier material which prevent virtually any permeation of refrigerant, yet remains flexible. Meet all specifications for low permeation construction. 740 psi working pressure, 3700 psi burst pressure.
68336A Robinair 36" Red Enviro-Guard Hose 45 Degree Quick Seal Fitting 1/4" Flare for R-12 and other gasses. Enviro-Guard Hoses are constructed of special barrier material which prevent virtually any permeation of refrigerant, yet remains flexible. Meet all specifications for low permeation construction. 740 psi working pressure, 3700 psi burst pressure.
Designed to protect recovery systems from debris and deposits that would normally harm your unit. Large filter capacity provides long life. All steel construction with enamel finish resists corrosion and rusting. 1/4" Male Flare fittings.
CRXTOSP1 Tank Overfill Protection Cable Shorting Plug allows the user to override the tank float safety device on most recovery units using a 3 pin brad Harrison cable. Screws in place at the cable end allowing the unit to start. (Always use a scale for accuracy when using this device) 30 & 50 pound tanks should never be filled to a level beyond 80% of tank capacity.
1/4 Flare Seal Cap with anchor retention strap prevents loss when not in use.
Scale Platform Used to secure the refrigerant tank to the scale for accurate measure.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Liquid Pump Seal Allows the head gaskets to be replaced on pumps equipped with Teflon gaskets and comes complete with instructions.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Red Light High Pressure Light / Tank Full Light - Indicates when the discharge pressure reaches 350 psi or when the recovery tank is full.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Liquid Refrigerant Pump Circulates the liquid contained in the tank throughout the recycling loop in a continuous flow. RA17068 Replacement Seal KitRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
RA17138 Robinair Compressor Start Switch For 17300 17350 17500 17500BRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
HandleRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Discontinued Compressor 17500 - Replace With RA19800 & RA19832 Pumps the refrigerant from vehicle being serviced into the ISV or tank, on or inside of unit, for storage.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Fan Used to keep the unit hermetic compressor and electrical components cool.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
System Relay 115 volt coil, double pole single throw normally open switch with dual sets of 15 amp contacts. Acts as a pilot from the circuit board usually carrying higher amp loads to protect smaller relays on board. Can be used for universal applications due to the high amp contact rating.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
COMP. 17501B/17503BRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Recovery Solenoid Normally closed automatic valve that prevents flow of refrigerant into the system oil separator while not powered.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
RA18759 Robinair Air Purge Gauge And Thermometer gives the operator a visual cue as to the air content of a cylinder during recycling mode. Operates on a pressure temperature equivalence similar to a pressure temperature chart. The temp scale reads from the red needle and the pressure scale reads from the green needle. All that is needed is to compare the needles on the gauge to determine if air is present.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Discharge Oil Separator (Old Style Float Type). Separates oil from refrigerant in the discharge gas stream. Internal turbulence causes incoming saturated refrigerant to vaporize. This is important to be sure oil droplets contained in the incoming refrigerant will drop out in the separator so they can be returned to the compressor.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Discharge Oil Separator (J Tube Type) replaces older float style units. - Separates oil from refrigerant in the discharge gas stream. Internal turbulence causes incoming saturated refrigerant to vaporize. This is important to be sure oil droplets contained in the incoming refrigerant will drop out in the separator so they can be returned to the compressor.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Evaporator / CondenserRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Ball Valve Assembly A manual valve that, when open, routes discharge pressure through the condenser.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
115 Volt Grounded recepticle that acessories plug intoRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Recycle Start Switch Energizes the liquid pump and air purge timer.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
System Oil Separator Separates oil from refrigerant. Internal heat causes incoming saturated vapor to evaporate. This is important to be sure no liquid enters the compressor and that oil droplets contained in the incoming refrigerant will drop out in the separator.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
High Pressure Cutout 17650 / 17655 A normally closed sensor that opens, stopping the recovery process when the compressor discharge pressure reaches 435 psi. SPDT Contact arrangement. 1/4 spade termination.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Upper Fan 17500B Cools compressor and electrical components inside of unit.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Upper Fan 17501B Cools compressor and electrical components inside of unit.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Inlet Stem AssemblyRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Solenoid Rebuild Kit Normally closed Solenoid Rebuild Kit - Used to rebuild certain solenoids in manifolds or discrete (RA19006) etc..Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Compressor Start Kit for older style compressors (check service for applications) .Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
115v Solenoid Coil Coil only, used to energize a normally closed solenoid that, when energized, allows flow. i.e. Recovery, Charge, vacuum, etc. NOTE: RA19258 Solenoid Rebuild KitRobinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
3/8" O-Ring (10 Pack)Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Compressor Pumps the refrigerant from system being serviced into the ISV or tank, on unit, for storage. If installing this as a retrofit replacement for the original compressor, see the installation tubing kit.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Compressor Retrofit Kit 17500 Series Copper lines and tubing used to retrofit unit for new style compressor.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Fastener Seal and hardware kit for Robinair recovery units is a service provider must have. This kit contains 38 of the most requested hardware and small maintenance items on most Robinair machines many of which are difficult or impossible to find by themselves, including gaskets seals, bolts and screws, pneumatic fittings, door latches, Torx screws, flare gaskets and other hard to find or specific related items. 3/8 Hose Gasket, 1/4 Fl Copper gasket, O'Rings, Screws Torx, Speed Nuts, Tinnerman U Clip, 1/2 Acme Jam nut, Pneumatic Fittings, Pan Head screws, Grommets, Door Latch Receptacle, Connector, Plastite connector, Bezel 7002K / 700Z, Door Latch Spring, Injector Bulkhead Fitting, Oil Injector Cap And Bulkhead Fitting, Vacuum Pump Fill Caps, Shreader Cores. Housed in a Double sided flip top case with extra space for other items.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
Main Power Switch Controls the electrical power between the power cord and the main board.Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.
One 1/4'' female flare to 3/8'' male flare brass adapters made in the USA using the highest level of brass consisting of 65% copper and 35% zinc which means high-tensile strength while resisting corrosion. The forging process of fittings maximize strength and eliminate cracking.