118039 Robinair Refrigerant Pressure Temperature Chart
Refrigerant Pressure Temperature Chart For 41600 Series Manifolds or Universal Application. Lists 12 refrigerants including R-12, R-22, R-134A, R-410A, R-502, R-401A, R-401B, R-402A, R-402B, R-404A Fits conveniantly on the rear of 41400, 41600, 40100 series gauges with protector.
Discontinued
19225 Robinair Float Switch Cable
Float Switch Cable Makes the connection between the float in the tank and the system relay. When the tank reaches 80% capacity, the float interrupts the control voltage to the system relay causing the unit to shut down.
74-099 CPS Magnetic Tank Thermometer 26?F To 120F? (-3?C To 49?C)
74-099 CPS Magnetic Tank Thermometer. 48 Point Temp Label Magnet, 26°F To 120F° (-3°C To 49°C). These magnetic temperature labels provide a safe, accurate, easy-to-read means for monitoring temperatures. Indicating strips use liquid crystal technology to display the current temperature at an economical cost. The strip will turn green when ambient temperature is reached. Great for tank temperature monitoring during recovery processes or air purge procedures.
CRXOS1 CPS Oil Separator
The CRXOS1 CPS Oil Separator provides a simple but effective means to remove small amounts of oil in the recovery stream for cleaner gas. Use in conjunction with a filter drier for even cleaner refrigerant for recharging. Equipped with standard 1/4" flare fittings and an inlet hose. When recovery is complete, simply drain the unit with supplied valve. Includes mounting hardware.
CRXTOS2 CPS CR Series Recovery Tank Overfill Protection Kit
CPS CR Series Recovery Tank Overfill Protection Kit provides a safe means of recovering refrigerant into a cylinder without the worry of overfilling it causing a potetially hazardous situation. Normally the technician would have to be present to safely recover with a scale, now you can hookup and walk away with out fear of overfulling your tank.
CRXTOS4 CPS Recovery Tank Overfill Protection Kit
Recovery Tank Overfill Protection Kit provides a safe means of recovering refrigerant into a cylinder without the worry of overfilling it causing a potentially hazardous situation. Normally the technician would have to be present to safely recover with a scale, now you can hookup and walk away with out fear of overfilling your tank. When the recovery cylinder reaches 80% capacity, the unit is shut off via a relay in the machine. Simply change cylinders and restart the unit. Works with any size cylinder with a 3-pin Brad Harison Plug and includes a shorting cap for working with tanks without a float.
CRXTOSP1 CPS 3 Pin Brad Harrison Tank Overfill Cable Shorting Plug
CRXTOSP1 Tank Overfill Protection Cable Shorting Plug allows the user to override the tank float safety device on most recovery units using a 3 pin brad Harrison cable. Screws in place at the cable end allowing the unit to start. (Always use a scale for accuracy when using this device) 30 & 50 pound tanks should never be filled to a level beyond 80% of tank capacity.
KT-5002A PROMAX 80% Tank Overfill Protection Installation Adapter
For use with the PROVAX Refrigerant Recovery Machines that do not have internal wired jack for the KT-5002 overfill protection plug and cable. Some late model units do not have the 3 wire socket installed from the factory and this will be needed to complete the installation of your float cable kit.