Product Features
- 3260 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 32.6MΩ; max resolution 0.1Ω
- Audible continuity
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Analog bar graph
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
The DMM 163 also features:
- RANGE: Allows the user to manually range the 183A instead of autoranging.
- DATA HOLD: Holds the reading on the display for easy viewing.
- AUTO OFF: Preserves battery life.
The 163 comes complete with the following accessories:
- Rubber Boot
- Test Lead Set
- Battery
- Instruction Manual
Model 163 Applications
- Thermocouples in furnaces or gas applications
- Heat anticipator current in thermostats
- Line voltage
- Voltage of direct drive DC motors
- Control circuit voltage
- Motor run and start capacitors
- Flame safeguard control current
- Heating element resistance (continuity)
- Compressor winding resistance
- Contactor and relay coil resistance
- Continuity of wiring
- Continuity of circuit breakers
- Temperature w/ optional temperature adapter
- Bar graph to indicate rapid fluctuations in measurements
Category Ratings:
- Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
- Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.
- Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
- Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power
Model 163 Specifications
|
DC Volts
|
Maximum Input: 1000V
Maximum Resolution: 0.1mV
Accuracy: +/-0.5%
|
AC Volts
|
Maximum Input: 750V
Maximum Resolution: 0.001mV
Accuracy: +/-1.2%
|
DC Amps
|
Maximum Input: 10A
Maximum Resolution: 0.1μA
Accuracy: +/-1%
|
AC Amps
|
Maximum Input: 10A
Maximum Resolution: 0.1μA
Accuracy: +/-2%
|
Resistance (Ohms)
|
Maximum Input: 32.6MΩ
Maximum Resolution: 0.1mΩ
Accuracy: +/-1%
|
Frequency
|
N/A
|
Capacitance
|
N/A
|
Inductance
|
N/A
|
Temperature
(K-Type Thermocouple)
|
N/A
|
Continuity
|
Audible at less than 20Ω
|
Diode
|
3V at 0.5mA maximum output
|
Duty Cycle
|
N/A
|
True RMS Responding
|
No
|
Conductance
|
No
|
Pulse Width
|
No
|
Data Hold
|
Yes
|
Min/Max Record
|
No
|
Time Stamp Logging
|
No
|
Relative Mode
|
No
|
Compare Mode
|
No
|
RS-232 Output
|
No
|
Process Loop Output
|
No
|
Sleep Mode / Auto Off
|
Yes
|
Protective Boot
|
Yes (standard)
|
Display Type
|
3260 count LCD with analog bargraph
|
Range Selection
|
Auto / Manual
|
Operating Temperature
|
32°F to 104°F (0°C to 40°C)
|
Storage Temperature
|
14°F to 122°F (-10°C to 50°C)
|
Humidity
|
80% non-condensing
|
Size
|
7.4” x 3.4” x 1.2” (187mm x 86mm x 33mm) with boot
|
Weight
|
12oz (340g) with boot
|
Battery Type
|
1.5V “AA” Alkaline (2)
|
Battery Life
|
200hrs Typical
|
OverInput Category
|
CAT III 600V
|
Agency Approval
|
cULus 61010-1, IEC 61010-1
|
Warranty
|
Limited Lifetime
|
|
|
|
|
|
|
Accessories for this product... |
|
|
|