Product Features
- True RMS Auto Ranging DMM offers increased accuracy over average responding multimeters
- 1MHz Oscilloscope can be used to view power signals to determine quality as well as correct amplitude and frequency, assisting in finding and preventing problems
- Trend Mode enables surges and dropouts to be graphed
- Communication to a PC using optional RS-232 cable and software
- cULus 61010-1
Model 440 Applications
- View industrial signals such as motor control, UPS, switching power supplies, and PLC controls with 1MHz bandwidth
- Capture noise spikes, glitches, and intermittents with 20 megasamples per second sampling rate
- Full autoranging, True RMS, DMM capabilities
- Measure resistance and test for continuity
- Continually updated display provides a live presentation
Category Ratings:
- Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
- Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.
- Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
- Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power
SPECIFICATIONS
IEC 1010 Over Voltage: CAT II - 1000V CAT III - 600V Pollution Degree 2
OSCILLOSCOPE FUNCTIONS
Horizontal
- Sample Rate: 20 Megasamples/second
- Record Length: 256 in all modes (pixel)
- Samples/Division: 20
- Update Rate: Real time
- Modes: Single shot
- Accuracy: ±0.01%
- Sweep Rate: 1µS to 1S in 1,2,5 sequence
Vertical
- Bandwidth: 1MHz
- Resolution: 8 bits
- Channels: Single
- Coupling: AC, DC
- Input Impedance: 1.11 M Ohm
- Accuracy: ±3%
- Max Input Volts: 1000 Vp-p
Triggering
- Type: Internal
- Coupling: AC, DC, Glitch Capture
- Slope: + or - edge
- Internal Trigger Sensitivity: 2/20 Division
Other
- Glitch Capture: Over 0.05 Horizontal division, 0.25 Vertical division spike. Minimum time 1µS
- Digital Trigger Delay Time: 0-512 Samples
- Logic Test Display: 3V & 5V CMOS, TTL
DIGITAL MULTIMETER FUNCTIONS
a. DCV
Range
|
Resolution
|
Accuracy
|
Impedance
|
400mV
|
0.1mV
|
±0.3% of reading,
±2 digits
|
More then 100MΩ
|
4V
|
0.001V
|
±0.3% of reading,
±2 digits
|
10MΩ
|
40V
|
0.01V
|
±0.3% of reading,
±2 digits
|
10MΩ
|
400V
|
0.1V
|
±0.3% of reading,
±2 digits
|
10MΩ
|
1000V
|
1V
|
±0.3% of reading,
±2 digits
|
10MΩ
|
b1. ACV (20Hz to 50Hz)
Range
|
Resolution
|
Accuracy
|
Impedance
|
300mV
|
0.1mV
|
±1.5% of reading,
±10 digits
|
1.11MΩ
|
3V
|
0.001V
|
±1.5% of reading,
±10 digits
|
1.11MΩ
|
30V
|
0.01V
|
±1.5% of reading,
±10 digits
|
1.11MΩ
|
300V
|
0.1V
|
±1.5% of reading,
±10 digits
|
1.11MΩ
|
750V
|
1V
|
±1.5% of reading,
±10 digits
|
1.11MΩ
|
b2. ACV (50Hz to 1kHz, 1kHz to 10kHz)
Range
|
Resolution
|
Accuracy
|
Impedance
|
300mV
|
0.1mV
|
±0.75% of reading,
±10 digits
|
1.11MΩ
|
3V
|
0.001V
|
±0.75% of reading,
±10 digits
|
1.11MΩ
|
30V
|
0.01V
|
±0.75% of reading,
±10 digits
|
1.11MΩ
|
300V
|
0.1V
|
±0.75% of reading,
±10 digits
|
1.11MΩ
|
750V
|
1V
|
(N/A for 1kHz to 10kHz)
|
1.11MΩ
|
b3. ACV (10kHz to 30kHz, 30kHz to 100kHz, 100kHz to 200kHz)
Range
|
Resolution
|
10kHz - 30kHz
|
30-100kHz
|
Impedance
|
Impedance
|
300mV
|
0.1mV
|
±2.5% of reading,
±30 digits
|
±4% of reading,
±200 digits
|
±10% of reading,
±300 digits
|
1.11MΩ
|
3V
|
0.001V
|
±2.5% of reading,
±30 digits
|
±4% of reading,
±200 digits
|
±10% of reading,
±300 digits
|
1.11MΩ
|
30V
|
0.01V
|
±2.5% of reading,
±30 digits
|
±4% of reading,
±200 digits
|
±10% of reading,
±300 digits
|
1.11MΩ
|
300V
|
0.1V
|
±2.5% of reading,
±30 digits
|
±4% of reading,
±200 digits
|
±10% of reading,
±300 digits
|
1.11MΩ
|
750V
|
1V
|
N/A
|
N/A
|
N/A
|
|
c. DCA
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400µA
|
0.1µA
|
±0.5% reading,
±5 digits
|
Fuse* (fast below) F600V, 0.5A, 31CM
|
4000µA
|
1µA
|
±0.5% reading,
±5 digits
|
Fuse* (fast below) F600V, 0.5A, 31CM
|
40mA
|
0.01mA
|
±0.5% reading,
±5 digits
|
Fuse* (fast below) F600V, 0.5A, 31CM
|
400mA
|
0.1mA
|
±0.5% reading,
±5 digits
|
Fuse* (fast below) F600V, 0.5A, 31CM
|
4A
|
0.001A
|
±0.75% reading,
±10 digits
|
F600V, 0.5A, 31CM
|
10A
|
0.01A
|
±0.75% reading,
±10 digits
|
F600V, 0.5A, 31CM
|
d. ACA
Range
|
Resolution
|
20-50Hz
|
50Hz-3kHz
|
3-10kHz
|
10-30kHz
|
300µA
|
0.1µA
|
±1% reading,
±10 digits
|
±0.75% reading,
±10 digits
|
±2% reading,
±20 digits
|
±2% reading,
±40 digits
|
3000µA
|
1µA
|
±1% reading,
±10 digits
|
±0.75% reading,
±10 digits
|
±2% reading,
±20 digits
|
±2% reading,
±40 digits
|
30mA
|
0.01mA
|
±1% reading,
±10 digits
|
±0.75% reading,
±10 digits
|
±2% reading,
±20 digits
|
±2% reading,
±40 digits
|
300mA
|
0.1mA
|
±1% reading,
±10 digits
|
±0.75% reading,
±10 digits
|
±2% reading,
±20 digits
|
N/A
|
3A
|
0.001A
|
±1% reading,
±10 digits
|
±0.75% reading,
±10 digits
|
N/A
|
N/A
|
10A
|
0.01A
|
±1% reading,
±10 digits
|
±0.75% reading,
±10 digits
|
N/A
|
N/A
|
e. OHM (Resistance, Ω)
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400Ω
|
0.1Ω
|
±0.3% reading,
±10 digits
|
600V DC or AC Peak
|
4kΩ
|
0.001kΩ
|
±0.3% reading,
±2 digits
|
600V DC or AC Peak
|
40kΩ
|
0.01kΩ
|
±0.3% reading,
±2 digits
|
600V DC or AC Peak
|
400kΩ
|
0.1kΩ
|
±0.3% reading,
±2 digits
|
600V DC or AC Peak
|
4MΩ
|
0.001MΩ
|
±1.0% reading,
±10 digits
|
600V DC or AC Peak
|
30MΩ
|
0.01MΩ
|
±1.5% reading,
±20 digits
|
600V DC or AC Peak
|
f. Continuity Buzzer
Test Voltage
|
Max Test Current
|
Overload Protection
|
3V
|
100 digits
|
600 V DC or Peak AC
|
g. Diode Test
Test Voltage
|
Max Test Current
|
Overload Protection
|
3V
|
Approx. 2.5mA
|
600 V DC or Peak AC
|
*Warning: Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating
i. Capacitance
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400.0nF
|
100pF
|
±3% reading,
±5 digits
|
600V DC or AC Peak
|
4.0µF
|
0.001µF
|
±3% reading,
±5 digits
|
600V DC or AC Peak
|
40.0µF
|
0.01µF
|
±3% reading,
±5 digits
|
600V DC or AC Peak
|
400.0µF
|
0.1µF
|
±3% reading,
±5 digits
|
600V DC or AC Peak
|
j. Frequency
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
100.00Hz
|
0.01Hz
|
±0.05% reading,
±1 digits
|
600V DC or AC Peak
|
1.0000kHz
|
0.1Hz
|
±0.05% reading,
±1 digits
|
600V DC or AC Peak
|
10.000kHz
|
1Hz
|
±0.05% reading,
±1 digits
|
600V DC or AC Peak
|
100.00kHz
|
10Hz
|
±0.05% reading,
±1 digits
|
600V DC or AC Peak
|
1.0000MHz
|
100Hz
|
±0.05% reading,
±1 digits
|
600V DC or AC Peak
|
2.0000MHz
|
100Hz
|
±0.05% reading,
±1 digits
|
600V DC or AC Peak
|
* * Sensitivity (square wave)
1Hz below N/A
2Hz to 1kHz 1V
1kHz to 2MHz 1.5V
GENERAL SPECIFICATIONS
Max. Volt. between any input and Ground
|
1000V
|
Basic DC Accuracy
|
0.3%
|
Frequency Counter Range
|
2 MHz
|
Meter AC Bandwidth
|
200 kHz
|
Waveform Display Bandwidth
|
1 MHz
|
Fuse Protection
|
mA: 0.5Amp/600VAC; A: 10Amp/600VAC
|
Display Type
|
Super-twist LCD, 160 x 240 pixels
|
Operating Temperature
|
0° to 50°C (32° to 122°F)
|
Storage Temperature
|
-20° to 60°C (-4 to 140°F)
|
Relative Humidity 0% to 80%
|
(0°-35°C / 32°-95°F)
0% to 70%: (35°-55°C / 95°-131°F)
|
Temp. Coefficient
|
0.1 x (Specified Accuracy) per °C for temperature <18°C to >28°C
|
Power Supply
|
Nicad Battery 7.2V, AA Cell x 8
|
Battery Life Time
|
5 Hours
|
Battery Charge Time
|
3 Hours
|
Safety Designed
|
Pollution degree 2, Overvoltage Cat. II 1000V, Cat III 600V per IEC 1010, UL3111 and C22.2 No. 1010-1
|
Size (H x L x W)
|
52 x 220 x 100mm
|
Weight
|
1 lb. 6 oz
|
|