TPI 183A 4,000 Count True RMS DMM W/ Temperature Capacitance Duty Cycle And Low Pass Filter W/ A106 A085 And GK13M - The 183A is a hand-held autoranging DMM. The 183A measures ACV, DCV, ACA, DCA, Resistance, Frequency, Duty Cycle, Diodes, Capacitance, Temperature and Continuity. The meter is also easy to use and built to last.
REC: Records Min/Max and Average readings during specified measurement intervals.
RANGE: Allows the user to manually range the 183A instead of autoranging.
HOLD: Holds the reading on the display for easy viewing.
REL: Displays the value as a difference to a reference value.
AUTO OFF: Preserves battery life.
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Features
- Duty cycle (% pulse width modulation) for measuring modulating gas valves
- Low pass filter for noisy environments
- Separate fuse (2) and battery compartment
- IR serial interface that can be used to input data to PC with optional A183
- High resolution (0.01) low DC microamp range for measuring flame safety control circuit
- Frequency, capacitance, temperature, data hold, min/max record, relative mode
- AC/DC volts, AC/DC amps, resistance, audible continuity and diode test
- 4,000 count
- True RMS for more accurate measurements
- Auto/manual ranging
- Temperature measurement
- Duty cycle to measure the amount of time the motor is on
- Low pass filter for noisy environments
- Separate fuse (2) and battery compartment
- IR serial interface
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
The 183A comes complete with the following accessories:
- 183A Instrument
- Zippered Vinyl Carrying Case
- Rubber Boot
- Test Lead Set
- Instruction Manual
Model 183A Applications
- Test run and start capacitors
- Measure ambient and duct temp
- Test control (thermostat, thermocouple, flame safety) and line voltages
- Measure resistance and test for continuity
- Line current up to 10amps (in series)
Category Ratings:
- Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
- Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.
- Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
- Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power
Model 183A Specifications
|
DC Volts
|
Maximum Input: 1000V
Maximum Resolution: 0.01mV
Accuracy: +/-0.05%
|
AC Volts
|
Maximum Input: 750V
Maximum Resolution: 0.01mV
Accuracy: +/-0.4%
|
DC Amps
|
Maximum Input: 10A
Maximum Resolution: 0.01μA
Accuracy: +/-0.8%
|
AC Amps
|
Maximum Input: 10A
Maximum Resolution: 0.01μA
Accuracy: +/-0.75%
|
Resistance (Ohms)
|
Maximum Input: 40MΩ
Maximum Resolution: 0.1mΩ
Accuracy: +/-0.05%
|
Frequency
|
Maximum Input: 10MHz
Maximum Resolution: 0.01Hz
Accuracy: +/-0.05%
|
Capacitance
|
Maximum Input: 4000µF
Maximum Resolution: 0.01nF
Accuracy: +/-3%
|
Inductance
|
N/A
|
Temperature
(K-Type Thermocouple)
|
Maximum Input: 2372°F (1300°C)
Maximum Resolution: 0.1°F / °C
Accuracy: +/-2%
|
Continuity
|
Audible at less than 300Ω
|
Diode
|
2.7V at 1mA maximum output
|
Duty Cycle
|
Range: 0.1 to 99.9%
Accuracy: 0.1% + 1 count
|
True RMS Responding
|
Yes
|
Conductance
|
No
|
Pulse Width
|
No
|
Data Hold
|
Yes
|
Min/Max Record
|
Yes
|
Time Stamp Logging
|
no
|
Relative Mode
|
Yes
|
|
|
|
|
|
|
|