Automotive tools & equipment

HVAC & Industrial supplies

Sales - parts -service


  Home > Air Conditioning Equipment > Diagnostic Equipment >

JL3KM2 Fieldpiece JL Kit-Dual Manometer

JL3KM2 Fieldpiece JL Kit-Dual Manometer
 
Our Price: $199.15


Product Code: FPIJL3KM2
Qty:

Description Prop65
 
Experience untethered freedom.
  • 1000′ Wireless range
  • Precise placement with untethered design
  • All-in-one static, gas and draft pressure
  • Record up to 8 readings at once* in Job Link App
The revolutionary new JL3KM2 Job Link® System Manometer probes give HVACR pros the freedom to work the way they want to — unrestricted by hoses, so technicians get readings from optimal locations on every system, every time.
Short hose length keeps things neat, and independent sensors allow for direct placement on test ports. Measure between zones without snaking a hose past the door. Dial in gas pressure of a furnace. Optimize total external static pressure of equipment. Pinpoint duct leaks and restrictions. Increase comfort and do more.
Product Features

Specifications
  • Minimum Device Requirement:BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com)
  • Compatible Media: Dry, non-corrosive gas
  • Pressure Port: Tube connector for flexible tubing (4.5 to 8mm ID)
  • Units of Measure: inWC, mmWC, mbar, psi, Pa
  • Accuracy and Ranges:
  • inWC: ±0.02 on 0.00 to ±2.00 (±1.5% FS on 2.00 to ±60.00);
  • mmWC: ±0.5 on 0.0 to ±51.0 (±1.5% FS on 51.0 to ±1500.0);
  • mbar: ±0.05 on 0.00 to ±5.00 (±1.5% FS on 5.00 to ±150.00);
  • psi: ±0.001 on 0.000 to ±0.072 (±1.5% FS on 0.072 to ±2.165);
  • Pa: ±5 on 0 to 498 (±1.5% FS on 498 to ±14930)
  • Maximum Overload Pressure: 321.08 inWC (11.6 psi; 80.0 kPa)
  • Battery Type: 2 x AAA, NEDA 24A, IEC LR03
  • Battery Life: 150 hours typical alkaline. LED slow-blinks red when battery replacement is needed.
  • Auto Power Off: 2 hours (APO can be disabled)
  • Wireless Range: 1000 feet (305 meters) line of sight. Obstructions affect distance.
  • Radio Frequency: 2.4 GHz
  • Operating Environment: -10°F to 122°F (-23°C to 50°C) at <75% RH
  • Storage Temperature: -10°F to 140°F (-23°C to 60°C) at <80% RH (with batteries removed)
  • Temperature Coefficient: 0.1 x (specified accuracy) per 1.8°F (-10°F to 64°F, 82°F to 122°F), per 1°C (-23°C to 18°C, 28°C to 50°C)
  • Weight: 0.30 lbs (137 g)


Browse for more products in the same category as this item:

Air Conditioning Equipment > Diagnostic Equipment
Air Conditioning Equipment > Temperature, Air Flow & Humidity