Schumacher PS-1562A Troubleshooting Guide
|
PROBLEM
|
POSSIBLE CAUSE
|
SOLUTION
|
Charger will not turn on when properly connected.
|
AC outlet is dead.
|
Check for an open fuse or
circuit breaker supplying the AC outlet.
|
Poor
electrical connec¬tion.
|
Check the power cord and
extension cord for as loose fitting plug.
|
Severely
discharged, but otherwise good, battery.
|
The battery may not want to
accept a charge due to a run-down state. Allow the charging to continue until
the battery has had a chance to recover sufficiently enough to take a charge.
If more than 20 minutes, stop charging and have the battery checked.
|
Clips
are not making a good connection to the battery.
|
Check for poor connec¬tion to
battery and frame. Make sure connection points are clean. Rock clips back and
forth for a better connection.
|
Battery
is defective.
|
Have the battery checked.
|
Reverse
connections at battery.
|
Unplug the charger and correct
the lead connec¬tions.
|
Charger makes a loud buzz or hum.
|
Transformer laminations vibrate
(buzz).
|
No problem, this is a normal
condition.
|
Shorted
Diode Assembly or Output Rectifier Assembly (hum).
|
Have charger checked by a
qualified technician.
|
CHARGING
(yellow) LED is flashing.
|
Indicates the charger is in abort mode.
|
See “Aborted Charge” in the
OPERATING INSTRUCTIONS Section.
|
Schumacher User Manual Link
|