Automotive tools & equipment

HVAC & Industrial supplies

Sales - parts -service


  Home > Multimeters & Test Instruments >

1P20B2 TPI Oscilloscope Probe 20 Mhz X 1 2M Cable Length

1P20B2 TPI Oscilloscope Probe 20 Mhz X 1 2M Cable Length
 
Price $28.60


Product Code: TPI1P20B2
Qty:

Description Prop65
 
TPI 1P20B2 Oscilloscope Probe 20 MHz X 1 2M Cable Length - This is a non-switchable passive oscilloscope probe. Selecting the correct oscilloscope probe ensures accuracy and can improve the performance of your test instrument. TPI offers a wide range of high quality oscilloscope probes designed to meet the most demanding applications.
Product Features

Specifications:

  • Model #: 1P20B2
  • Bandwidth: 15MHz
  • Attenuation: x1
  • Cable Length: 2 meters
  • Input / Impedance: 1Meg 47pF
  • Max Input V DC + Peak AC: 150 Volt
  • Rise Time: 23ns
  • Compensation Range: N/A
  • Readout: N/A
  • IEC1010: N/A

Applications

  • Use TPI Probes with Bench Top, Portable, Analog, and Oscilloscopes
  • Logic signal and waveform tests
  • Measure voice / data signals
  • Analyze power quality
  • Test motor control circuits

Several important factors must be taken into account when selecting the proper probe:

The probe should have sufficient bandwidth and rise time for the test instrument and application. Choose a probe with at least an equal bandwidth as the scope it will be used with. For best performance a probe with twice the bandwidth as the scope should be selected. For oscilloscope probes, the input capacitance of your oscilloscope should be within the compensation range specification of the probe. In addition, if your oscilloscope has readout function, select a probe with this capability. For differential probes, make sure the maximum differential voltage is adequate for your application and the common mode rejection specification meets the requirements of the tests being performed.

Terminology:

Attenuation: Ratio of the output signal to the input signal. Attenuation should remain constant decreasing by 3dB only as the frequency increases to the maximum bandwidth.

Bandwidth: The maximum -3dB frequency that can be expected.

Cable Length: Length of the cable from the end of the probe to the end of the connector. It is important to use a probe with just enough cable length for your needs. Long cables increase the capacitance and propagation delay of the probe.

CMRR (Common Mode Rejection Ratio): A measure of a differential probes ability to reject any signals common to both test points in a differential measurement

Compensation Range: The range a probe can be compensated to match the input capacitance of the test equipment it is being used with.

IEC 1010: Probes with the IEC 1010 category rating have been designed for safety.

Input Impedance: The total resistance and capacitance as measured at the tip of the probe. This specification is used to define the loading effect of a probe. At frequencies under 1MHz the input resistance of the probe will have the most influence. At higher frequencies the input capacitance will have the most influence.

Max Input Voltage: The maximum voltage the probe can be used at.

Max Differential Voltage: The maximum differential voltage that can be measured by a differential probe

Readout: Probes with this capability are compatible with readout function oscilloscopes that automatically detect and display the attenuation factor of the probe.

Rise Time: The time required for the leading edge of a pulse to rise from 10% to 90% of its final value.



Browse for more products in the same category as this item:

Multimeters & Test Instruments
Multimeters & Test Instruments > Oscilloscopes (Handheld) > Non-Switchable Passive Oscilloscope Probes