Automotive tools & equipment

HVAC & Industrial supplies

Sales - parts -service


  Home > Multimeters & Test Instruments >

440 TPI Oscilloscope 1 MHz True RMS DMM Logic And Component Test Leads And Charger

440 TPI Oscilloscope 1 MHz True RMS DMM Logic And Component Test Leads And Charger
 
Price $362.05


Product Code: TPI440
Qty:

Description Prop65
 

TPI 440 Oscilloscope 1 MHz True RMS DMM Logic And Component Test Leads And Charger - The TPI 440 is a hand-held oscilloscope plus autoranging DMM. The instruments large, backlit LCD display shows a reading and waveform simultaneously. In addition to the standard functions of ACV, DCV, ACA, DCA, Ω, Diode Test and Continuity Buzzer; the 440 measures Frequency (Hz),Capacitance, Logic and Component test functions. The 440 also has RS232 output and software for interfacing with a PC is offered as an optional accessory.

The versatile handheld TPI 440 is a customer winner.

Technicians appreciate the bright backlight of the 3" x 3" cold cathode flourescent display and rugged construction inside and out.

6 Instruments in 1:

Auto Ranging 4,000 Count True RMS DMM: TPI’s 440 has 9 measurement functions and 0.3% basic DC accuracy.

1 MHz Oscilloscope: View industrial power signals such as motor controls, UPS, switching power supplies, and PLC controls with detail and clarity.

Trend Mode: Graph readings over a predetermined time period to check for surges or dropouts.

Component Test: Check voltage-current signatures on resistors, capacitors, and semiconductors.

Logic Test: Indicates transitions up to 2 MHz.

Frequency Counter: Measure low frequency signals from 1Hz to 2 MHz and display duty cycle, pulse width and period.

PC/Printer Compatibility to RS-232C Port Optional accessory A402 allows user to download data or waveforms to PC for archiving, processing, and report generation. Ideal for extended monitoring.

Approvals: Meets CE and IEC 1010 requirements

True RMS: Needed to accurately measure non-sinusoidal AC voltage and current waveforms found on many control and circuits

Auto Set: 440 automatically sets-up the scope depending on the magnitude of the signal being measured

Real Time Update:Tracks events as they happen

Glitch Capture: Finds spikes in signals

Relative Mode: LCD displays the difference between the measured value and a stored value

Trend Mode: Graphs signals to find problems with circuits

Record Mode: Records Min/Max and Average values. Time reference when value was obtained

Compare Mode: Compares stored value with measured value for matching components

Relative % Mode: Displays measured value as a percentage of stored value for checking component tolerances

RS232 Output: Transfers data directly to a PC while measuring

Back Light: Allows viewing in any light condition

Autorange: Automatically selects best range for measurement

Low Battery Indicator: Battery should be charged when battery symbol displays on LCD


Product Features
  • True RMS Auto Ranging DMM offers increased accuracy over average responding multimeters
  • 1MHz Oscilloscope can be used to view power signals to determine quality as well as correct amplitude and frequency, assisting in finding and preventing problems
  • Trend Mode enables surges and dropouts to be graphed
  • Communication to a PC using optional RS-232 cable and software
  • cULus 61010-1

Model 440 Applications

  • View industrial signals such as motor control, UPS, switching power supplies, and PLC controls with 1MHz bandwidth
  • Capture noise spikes, glitches, and intermittents with 20 megasamples per second sampling rate
  • Full autoranging, True RMS, DMM capabilities
  • Measure resistance and test for continuity
  • Continually updated display provides a live presentation

Category Ratings:

  • Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.

  • Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.

  • Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.

  • Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power

SPECIFICATIONS

IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2

OSCILLOSCOPE FUNCTIONS

Horizontal

  • Sample Rate: 20 Megasamples/second
  • Record Length: 256 in all modes (pixel)
  • Samples/Division: 20
  • Update Rate: Real time
  • Modes: Single shot
  • Accuracy: ±0.01%
  • Sweep Rate: 1µS to 1S in 1,2,5 sequence

Vertical

  • Bandwidth: 1MHz
  • Resolution: 8 bits
  • Channels: Single
  • Coupling: AC, DC
  • Input Impedance: 1.11 M Ohm
  • Accuracy: ±3%
  • Max Input Volts: 1000 Vp-p

Triggering

  • Type: Internal
  • Coupling: AC, DC, Glitch Capture
  • Slope: + or - edge
  • Internal Trigger Sensitivity: 2/20 Division

Other

  • Glitch Capture: Over 0.05 Horizontal division, 0.25 Vertical division spike. Minimum time 1µS
  • Digital Trigger Delay Time: 0-512 Samples
  • Logic Test Display: 3V & 5V CMOS, TTL

DIGITAL MULTIMETER FUNCTIONS

a. DCV

    Range Resolution Accuracy Impedance
    400mV 0.1mV ±0.3% of reading,
    ±2 digits
    More then 100MΩ
    4V 0.001V ±0.3% of reading,
    ±2 digits
    10MΩ
    40V 0.01V ±0.3% of reading,
    ±2 digits
    10MΩ
    400V 0.1V ±0.3% of reading,
    ±2 digits
    10MΩ
    1000V 1V ±0.3% of reading,
    ±2 digits
    10MΩ

b1. ACV (20Hz to 50Hz)

    Range Resolution Accuracy Impedance
    300mV 0.1mV ±1.5% of reading,
    ±10 digits
    1.11MΩ
    3V 0.001V ±1.5% of reading,
    ±10 digits
    1.11MΩ
    30V 0.01V ±1.5% of reading,
    ±10 digits
    1.11MΩ
    300V 0.1V ±1.5% of reading,
    ±10 digits
    1.11MΩ
    750V 1V ±1.5% of reading,
    ±10 digits
    1.11MΩ

b2. ACV (50Hz to 1kHz, 1kHz to 10kHz)

    Range Resolution Accuracy Impedance
    300mV 0.1mV ±0.75% of reading,
    ±10 digits
    1.11MΩ
    3V 0.001V ±0.75% of reading,
    ±10 digits
    1.11MΩ
    30V 0.01V ±0.75% of reading,
    ±10 digits
    1.11MΩ
    300V 0.1V ±0.75% of reading,
    ±10 digits
    1.11MΩ
    750V 1V (N/A for 1kHz to 10kHz) 1.11MΩ

b3. ACV (10kHz to 30kHz, 30kHz to 100kHz, 100kHz to 200kHz)

    Range Resolution 10kHz - 30kHz 30-100kHz Impedance Impedance
    300mV 0.1mV ±2.5% of reading,
    ±30 digits
    ±4% of reading,
    ±200 digits
    ±10% of reading,
    ±300 digits
    1.11MΩ
    3V 0.001V ±2.5% of reading,
    ±30 digits
    ±4% of reading,
    ±200 digits
    ±10% of reading,
    ±300 digits
    1.11MΩ
    30V 0.01V ±2.5% of reading,
    ±30 digits
    ±4% of reading,
    ±200 digits
    ±10% of reading,
    ±300 digits
    1.11MΩ
    300V 0.1V ±2.5% of reading,
    ±30 digits
    ±4% of reading,
    ±200 digits
    ±10% of reading,
    ±300 digits
    1.11MΩ
    750V 1V N/A N/A N/A

c. DCA

    Range Resolution Accuracy Overload Protection
    400µA 0.1µA ±0.5% reading,
    ±5 digits
    Fuse* (fast below) F600V, 0.5A, 31CM
    4000µA 1µA ±0.5% reading,
    ±5 digits
    Fuse* (fast below) F600V, 0.5A, 31CM
    40mA 0.01mA ±0.5% reading,
    ±5 digits
    Fuse* (fast below) F600V, 0.5A, 31CM
    400mA
    0.1mA ±0.5% reading,
    ±5 digits
    Fuse* (fast below) F600V, 0.5A, 31CM
    4A 0.001A ±0.75% reading,
    ±10 digits
    F600V, 0.5A, 31CM
    10A 0.01A ±0.75% reading,
    ±10 digits
    F600V, 0.5A, 31CM

d. ACA

    Range Resolution 20-50Hz 50Hz-3kHz 3-10kHz 10-30kHz
    300µA 0.1µA ±1% reading,
    ±10 digits
    ±0.75% reading,
    ±10 digits
    ±2% reading,
    ±20 digits
    ±2% reading,
    ±40 digits
    3000µA 1µA ±1% reading,
    ±10 digits
    ±0.75% reading,
    ±10 digits
    ±2% reading,
    ±20 digits
    ±2% reading,
    ±40 digits
    30mA 0.01mA ±1% reading,
    ±10 digits
    ±0.75% reading,
    ±10 digits
    ±2% reading,
    ±20 digits
    ±2% reading,
    ±40 digits
    300mA
    0.1mA ±1% reading,
    ±10 digits
    ±0.75% reading,
    ±10 digits
    ±2% reading,
    ±20 digits
    N/A
    3A 0.001A ±1% reading,
    ±10 digits
    ±0.75% reading,
    ±10 digits
    N/A
    N/A
    10A 0.01A ±1% reading,
    ±10 digits
    ±0.75% reading,
    ±10 digits
    N/A
    N/A

e. OHM (Resistance, Ω)

    Range Resolution
    Accuracy Overload Protection
    400Ω 0.1Ω ±0.3% reading,
    ±10 digits
    600V DC or AC Peak
    4kΩ 0.001kΩ ±0.3% reading,
    ±2 digits
    600V DC or AC Peak
    40kΩ 0.01kΩ ±0.3% reading,
    ±2 digits
    600V DC or AC Peak
    400kΩ 0.1kΩ ±0.3% reading,
    ±2 digits
    600V DC or AC Peak
    4MΩ 0.001MΩ ±1.0% reading,
    ±10 digits
    600V DC or AC Peak
    30MΩ 0.01MΩ ±1.5% reading,
    ±20 digits
    600V DC or AC Peak

f. Continuity Buzzer

    Test Voltage
    Max Test Current
    Overload Protection
    3V 100 digits 600 V DC or Peak AC

g. Diode Test

    Test Voltage
    Max Test Current
    Overload Protection
    3V Approx. 2.5mA
    600 V DC or Peak AC

*Warning: Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating

i. Capacitance

    Range Resolution Accuracy Overload Protection
    400.0nF
    100pF ±3% reading,
    ±5 digits
    600V DC or AC Peak
    4.0µF 0.001µF ±3% reading,
    ±5 digits
    600V DC or AC Peak
    40.0µF 0.01µF ±3% reading,
    ±5 digits
    600V DC or AC Peak
    400.0µF 0.1µF ±3% reading,
    ±5 digits
    600V DC or AC Peak

j. Frequency

    Range Resolution Accuracy Overload Protection
    100.00Hz 0.01Hz ±0.05% reading,
    ±1 digits
    600V DC or AC Peak
    1.0000kHz 0.1Hz ±0.05% reading,
    ±1 digits
    600V DC or AC Peak
    10.000kHz
    1Hz ±0.05% reading,
    ±1 digits
    600V DC or AC Peak
    100.00kHz 10Hz ±0.05% reading,
    ±1 digits
    600V DC or AC Peak
    1.0000MHz
    100Hz ±0.05% reading,
    ±1 digits
    600V DC or AC Peak
    2.0000MHz 100Hz ±0.05% reading,
    ±1 digits
    600V DC or AC Peak

* * Sensitivity (square wave)
1Hz below N/A
2Hz to 1kHz 1V
1kHz to 2MHz 1.5V

GENERAL SPECIFICATIONS

    Max. Volt. between
    any input and Ground
    1000V
    Basic DC Accuracy
    0.3%
    Frequency Counter Range
    2 MHz
    Meter AC Bandwidth
    200 kHz
    Waveform Display Bandwidth
    1 MHz
    Fuse Protection
    mA: 0.5Amp/600VAC; A: 10Amp/600VAC
    Display Type
    Super-twist LCD, 160 x 240 pixels
    Operating Temperature
    0° to 50°C (32° to 122°F)
    Storage Temperature
    -20° to 60°C (-4 to 140°F)
    Relative Humidity 0% to 80% (0°-35°C / 32°-95°F)
    0% to 70%: (35°-55°C / 95°-131°F)
    Temp. Coefficient
    0.1 x (Specified Accuracy) per °C for temperature <18°C to >28°C
    Power Supply Nicad Battery 7.2V, AA Cell x 8
    Battery Life Time
    5 Hours
    Battery Charge Time
    3 Hours
    Safety Designed
    Pollution degree 2, Overvoltage Cat. II 1000V, Cat III 600V per IEC 1010, UL3111 and C22.2 No. 1010-1
    Size (H x L x W)
    52 x 220 x 100mm
    Weight 1 lb. 6 oz

Accessories for this product...
A301 TPI Temperature Adapter W/Gk11M And Battery A296 TPI AC/DC Clamp-On Accessory For DMM's (0 To 1600 Amps AC) A150 TPI Screw On Alligator Clips For The A050 A075 A085 A402 TPI Software And RS232 Cable For 440 Scopeplus
Price $39.00

Add
Price $73.75

Add
Price $4.00

Add
Price $52.05

Add
A301 TPI Temperature Adapter W/Gk11M And Battery A296 TPI AC/DC Clamp-On Accessory For DMM's (0 To 1600 Amps AC) A150 TPI Screw On Alligator Clips For The A050 A075 A085 A402 TPI Software And RS232 Cable For 440 Scopeplus
A702 TPI Carbon Monoxide Accessory With Audio And Visual Alarm For DMM's A256 TPI AC/DC Clamp-On Accessory For DMM’s (0 To 400 Amps) A115 TPI Thermocouple Adapter For Gas Valves TLS2000B TPI Deluxe Test Lead Kit

Add
Price $73.75

Add
Price $6.82

Add
Price $39.16

Add
A702 TPI Carbon Monoxide Accessory With Audio And Visual Alarm For Dmms A256 TPI AC/DC Clamp-On Accessory For DMM’s (0 To 400 Amps) A115 TPI Thermocouple Adapter For Gas Valves TLS2000B TPI Deluxe Test Lead Kit
A900 TPI Soft Carrying Case With Shoulder Strap For 440 And Multiple Instruments A110 TPI 10 Amp/600V Ul Ceramic Fuse For 100 Series DMM’s (2 Each) A104 TPI 0.5 Amp/600V Ul Ceramic Fuse For 100 Series DMM’S (2 Each) A251 TPI AC Clamp-On Accessory For DMM's (0 To 400 Amps)
Price $19.56

Add
Price $5.00

Add
Price $5.00

Add
Price $45.95

Add
A900 TPI Soft Carrying Case With Shoulder Strap For 440 And Multiple Instruments A110 TPI 10 Amp/600V Ul Ceramic Fuse For 100 Series Dmm’S (2 Each) A104 TPI 0.5 Amp/600V Ul Ceramic Fuse For 100 Series Dmm’S (2 Each) A251 TPI AC Clamp-On Accessory For DMM's (0 To 400 Amps)
A620 TPI 500Psi Pressure/Vacuum Adapter
Price $251.70

Add
A620 TPI 500Psi Pressure/Vacuum Adapter


Browse for more products in the same category as this item:

Multimeters & Test Instruments
Multimeters & Test Instruments > Oscilloscopes (Handheld)