|
|
|
|
BLACKMAX digital manifolds from CPS Products, Inc. combine the latest manifold design and electronic measurement features into one easy-to-use, accurate and water resistant product in a rugged nylon plastic housing, incorporating a durable elastomeric keypad and large backlighted LCD display. The MD100VHE CPS 4 Valve Digital Manifold features A water resistant High Strength Glass Filled Nylon Housing provides ample protection for today's tough environments. 2 Clamp Temperature Probes for testing sub-cooling, super heat and bubble / dew point of 93 of the most commonly used refrigerants, The MD50 & MD100 provide many functions such as pressure, vacuum leak and decay tests. The optional CPS vacuum accessory MDXVG turns the digital manifold into an accurate Vacrometer.. 5 Foot Ball Valve Hoses provide ample length without getting tied up on the roof.
Tough: Precision Machined Anodized Aluminum Manifold Body. Proprietary Vortech Valve Systems (certified to 10 microns). High-impact polycarbonate LCD Window. Accurate: Performs pressure decay and vacuum rise tests. One-touch access to your 5 favorite refrigerants. One key ON/OFF and function select. Compatible with R744 subcritical CO2 Refrigerants. 2 Pressures, 2 Temperatures & Vacuum. Visible: Advanced sight glass design. 25 hours of continuous use with full backlight illumination. Temperature: Superior Thermistor Sensors for +/- 0.4 Degrees Fahrenheit (+/- 0.2 Degrees Celsius) Accuracy. Simultaneously Displays: HI & LO Pressures, Superheat & Subcooling HI & LO Pressures, T1 & T2HI & LO Pressures, Saturation T1 & Saturation T2HI & LO Pressures, Displays T1, T2 & Delta T Vacuum / Pressure: Direct System Attachment achieves +/- 10 microns from 0 to 25,000 microns, Vacuum Rise and Pressure Decay Test Functions. The unit allows for Pressure Decay or Vacuum Decay Testing for accurate system diagnostics and leak testing. 1% of reading Pressure. Preloaded with 93 of the most common Refrigerants.
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Features
- Vacuum: Direct System Attachment achieves +/- 10 microns from 0 to 25,000 microns
- Temperature: Superior Thermistor Sensors for +/- 0.4 Degrees Fahrenheit (+/- 0.2 Degrees Celsius) Accuracy
- Pressure: 1% of reading Pressure
- Water Resistant High Strength Glass Filled Nylon Housing
- Vacuum Rise and Pressure Decay Test Functions
- Simultaneously Displays:HI & LO Pressures, Superheat & Sub-cooling, HI & LO Pressures, T1 & T2 HI & LO Pressures, Saturation T1 & Saturation T2 HI & LO Pressures, Displays T1, T2 & Delta T
- Proprietary Vortech Valve Systems (certified to 10 microns)
- Preloaded with over 90 of the most common Refrigerants
- Precision Machined Anodized Aluminum Manifold Body
- Performs pressure decay and vacuum rise tests
- One-touch access to your 5 favorite refrigerants
- One key ON/OFF and function select
- High-impact polycarbonate LCD Window
- Compatible with R744 sub-critical CO2 Refrigerants
- Advanced sight glass design
- 25 hours of continuous use with full back-light illumination
- 2 Pressures, 2 Temperatures & Vacuum
Manifold Specifications
High side pressure range: -14.7 to 800.0 PSIG (-1.0 to 55 bar) Low side pressure range: -14.7 to 800.0 PSIG (-1.0 to 55 bar) Pressure reading accuracy: +/- 1% of reading or +/- 0.5 PSIG (+/- 0.05bar) Pressure reading resolution: 0.5 PSIG (0.05 bar) High and low side burst pressure: 1500.0 PSIG (103.4 bar) High side temperature range: -58.0 °F to 302 °F (-50 °C to 150°C) Low side temperature range: -58.0 °F to 302 °F (-50 °C to 150°C) Temperature reading accuracy: +/- 0.36 °F (+/- 0.2°C) Vacuum indication accuracy: +/- 10 microns (requires MDXVG accessory) SH, SC and saturation temperature accuracy: +/- 0.5°F (+/- 0.3°C) Instrument working temperature: -4.0 °F to 122°F (-20°C to 50°C) Instrument working RH range: 0% to 100% non-condensing. Total number of stored refrigerants: 93 APO (Automatic Power Off): 10 minutes. Can be disabled by user. MD100 size: 8.1 in. L x 3.5 in. H x 7.0 in. W MD50 size: 8.1 in. L x 2.5 in. H x 7.0 in. W MD100 weight: 3.3 lb. MD50 weight: 3.0 lb
Display Life Using 4 industrial alkaline AA batteries (included): Backlight full ON: 25+ hours continuous duty Backlight full OFF: 60+ hours continuous duty
Using 4 Rechargeable NiMH AA batteries (not included): Backlight full ON: 20+ hour continuous duty from full charge Backlight OFF: 50+ hours continuous duty from full charge
Vacuum Gauge Accessory Specifications
SENSOR: Type: Self - heated thermistor bridge with integral temperature compensation from 0 to 50°C (32 to 122 °F). Display pressure range: Two scales with auto-ranging; 0 to 9,990 microns with 10 micron resolution up-ranging to 9.90 to 25.90 Torricelli. Above 25.90 Torricelli the display shows -- -- -- - Maximum Working pressure: 400 PSIG
ACCURACY: +/- 10% of reading or +/- 10 microns, whichever is greater.
OPERATING TEMPERATURE RANGE: Compensated (accuracy as stated): 0°C TO 50°C (32°F TO 122°F) Non-compensated (add +/- 0.5% of reading error for every °C outside compensated range): -10 to 0°C (14 to 32°F)
OPERATING AND STORAGE HUMIDITY: 0 to 95%, non-condensing.
STORAGE TEMPERATURE: -40 to 85°C (-40 to 185°F)
Charger Accessory Specifications
OPERATING TEMPERATURE RANGE: 0°C TO 50°C (32°F TO 122°F) OPERATING & STORAGE HUMIDITY: 0-95%. STORAGE TEMPERATURE: -40 to 85°C (-40 to 185°F) POWER SOURCE: 100-240VAC input, 9VDC 2.0 amp maximum output BATTERY TYPE: AA size, NiMH rechargeable, approximate battery life is 20,000 to 50,000 hours* RECHARGEABLE BATTERY CYCLE LIFE: 1000 recharges * based on useage with or without the LCD backlight energized.
MD50 and MD100 manifolds are pre-loaded with 93 of the most
common refrigerants.
|
R11
|
R401A
|
R421A
|
R113
|
R401B
|
R421B
|
R114
|
R401C
|
R422A / M079
|
R115
|
R402A
|
R422B
|
R116
|
R402B
|
R422C
|
R12
|
R403A
|
R422D / M029
|
R123
|
R403B
|
R423A / 39TC
|
R123A
|
R404A
|
R424A
|
R1234YF
|
R405A
|
R425A
|
R124
|
R406A
|
R426A
|
R125
|
R407A
|
R427A / M089 / FX100
|
R1270
|
R407B
|
R428A
|
R13
|
R407C
|
R434A
|
R134
|
R407D
|
R437A / M049PLUS
|
R134A
|
R407F
|
R438A / M099
|
R13B1
|
R408A
|
R500
|
R141B
|
R409A
|
R501
|
R142B
|
R41
|
R502
|
R143
|
R410A
|
R503
|
R143A
|
R410B
|
R504
|
R152A
|
R411A
|
R507 or R507A
|
R176
|
R411B
|
R508A
|
R21
|
R412A
|
R508B
|
R218
|
R413A / M049
|
R509 or R509A
|
R22
|
R414A
|
R600
|
R23
|
R414B
|
R600A
|
R236ea
|
R415A
|
R601
|
R236FA
|
R416A
|
R601A
|
R245ca
|
R417A / M059
|
R744
|
R245fa
|
R418A
|
(Sub-critical range only)
|
R290
|
R419A
|
|
R32
|
R420A
|
|
|
|
|
|
|
|
Accessories for this product... |
|
|
|