Product Features
QUICK AND SIMPLE SET UP. All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need toperform fuel selection every time the analyzer is turned on.
- Range: 0 ~ 9,999ppm <10,000ppm: 1.000 ~ 9.999%
- 1 ppm sensitivity
- Pump driven
- Auto zero
- Pump driven for fast response
- Store function to save up to 50 readings
- Will not shut off if 15 ppm CO is present for increased safety
- Push on fittings for fast and easy use
- Optional A740 IR printer available for hard copies of test results
- Large easy to read backlit display
Model 706 Applications:
- Check forklift exhaust gases for the presence and location of carbon monoxide
Don’t expose yourself to Carbon Monoxide!
Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.
9ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
50ppm: The Federal OSHA standard for continuous exposure in any eight hour period.
200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours.
400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA.
800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes.
1600ppm*: Headache, dizziness, and nausea within 20 minutes. Death within 1 hour.
3200ppm*: Headache, dizziness, and nausea within 5-10 minutes. Death within 30 minutes.
6400ppm*: Headache, dizziness, and nausea within 1-2 minutes. Death within 10-15 minutes.
12800ppm*: Death within 1-3 minutes.
* With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.
Model 706 Specifications
|
Carbon Monoxide (CO) Measurement
|
Range 0 – 9.999%
|
Accuracy
|
±5ppm or 5% of reading whichever is greater
|
Resolution
|
1ppm 0 to 9999ppm 0.001% > 9999ppm
|
Data Storage
|
Yes
|
Time/Date Stamp of Stored Data
|
Yes
|
IR Printer Port
|
Yes
|
Flue Probe
|
Yes
|
Internal Pump
|
Yes
|
Combustible Gas Leak Detection
|
No
|
Backlight
|
Yes
|
Alarm
|
Audible
|
Power Supply
|
1.5V AA (3)
|
Dimensions
|
3.75”x 8” x 3” (95 x 303 x 76 mm)
|
Weight
|
1.1lbs (500g)
|
Warranty
|
3-year limited warranty