Product Features
- Measure flame safety control current
- Test run and start capacitors and motors
- Measure motor run current and capture peak motor start up amperage
- Measure heat anticipator current
- Determine thermocouple voltage
- Test line and control voltages
- Measure heating element resistance
- Measure air temperature in ducts
- Test for the presence of voltage in circuits without contacting the circuit
- Measure temperature differential using relative mode
- 400 Amps AC
- Measure motor in-rush current and run current
- Measure temperature differential using relative mode
- Frequency, Min/Max/Record, Data Hold and Peak Hold
- Up to 40,000 microfarads to test start and run capacitors
- 4,000 count display with 41 segment analog bar graph
- CAT III 600V rated
- cULus 61010
- 3-year limited warranty
The 270 comes complete with the following accessories:
- Carrying Pouch
- Test Lead Set
- Temperature Probe
- Instruction Manual
- Battery & Fuse
Model 270 Applications
- Measure flame safety control current
- Test run and start capacitors and motors
- Measure motor run current and capture peak motor start up amperage
- Measure heat anticipator current
- Determine thermocouple voltage
- Test line and control voltages
- Measure heating element resistance
- Measure air temperature in ducts
- Test for the presence of voltage in circuits without contacting the circuit
- Measure temperature differential using relative mode
Perform the following tests and/or measurements with the 270 and the appropriate function:
HVAC/R
- DCmV - Thermocouples in furnaces
- ACA - Heat anticipator current in thermostats
- ACV - Line voltage
- ACV or DCV - Control circuit voltage
- OHMS - Compressor winding resistance
- OHMS - Continuity of wiring
- CAP - Motor start and run capacitors
- ACA - Motor and compressor start up current
- Hz - Frequency on controls and line voltage
- TEMP - Air duct temperatures
- ALL - Bar graph to indicate rapid fluctuations
ELECTRICAL
- ACV - Measure line voltage
- ACA - Measure line current
- OHMS - Continuity of circuit breakers
- DCV - Voltage of direct drive DC motors
- ACA - Start up current of motors, relays, contactors and transformers
ELECTRONIC
- ACV - Measure power supply voltage
- ACA - Measure power supply current
- OHMS - Continuity of circuit breakers and fuses
Model 270 Specifications
DC Voltage
- Max Range: 600V
- Max Resolution: 0.1mV
- Basic Accuracy: 0.5%
AC Voltage
- Max Range: 600V
- Max Resolution: 0.1mV
- Basic Accuracy: 1.2%
DC Amps: N/A
DC Microamps
- Max Range: 400uA
- Max Resolution: 0.01uA
- Basic Accuracy: 3%
AC Amps
- Max Range: 400A
- Max Resolution: 0.1A
- Basic Accuracy: 3%
Resistance
- Max Range: 40MΩ
- Max Resolution: 0.1Ω
- Basic Accuracy: 1%
Frequency
- Max Range: 400MHz
- Max Resolution: 0.1Hz
- Basic Accuracy: 1%
Capacitance
- Max Range: 40mF
- Max Resolution: 0.001nF
- Basic Accuracy: 1%
Temperature
- Max Range: 1000°F
- Max Resolution: 0.1°F
- Basic Accuracy: 1%
Non-Contact Voltage (NCV): 24VAC and above
Continuity Buzzer: <35Ω
Diode Test: 1.5mA Max
True RMS Response: No
Peak Hold: No
Relative Mode: No
Min/Max Record: No
Data Hold: Yes
% Total Harmonic Distortion: No
Range Selection: Auto / Manual
Display Type: 4000 count LCD with analog bargraph
Operating Temperature: 32°F to 113°F
Relative Humidity: 80% non-condensing
Storage Temperature: -4°F to 140°F
Battery Type: 9V (MN1604)
Battery Life: 80hrs typical
Auto Off / Sleep Mode: Yes
Dimensions: (H x L x W) 1.3” x 10” x 2.5”
Weight: 0.8lb
Agency Approval
- CE IEC 61010: CAT III, 600V cULus 61010
|