The GR8-1200 Multi-tasking Battery and Electrical Diagnostic Station combines the diagnostic charging expertise of the GR8 with EXP Battery and Electrical System Diagnostics to create a complete, flexible and expandable diagnostic station. The GR8-1200 features the new Multi-tasking Bridge, which allows the user to perform battery and electrical diagnostics on other vehicles while the charger is in use. That means you can now more effectively multi-task in the garage and get more value out of one complete diagnostic station. Simply connect the test clamps to perform a full battery and electrical system analysis. If the battery needs charging, connect the charger clamps and the GR8 takes over.
Wireless Multi-Tasking Multi-tasking means having full electrical diagnostics available for other vehicles while another diagnostic charger function is in process. When a battery is discovered that needs charging, simply connect the charger clamps and the diagnostic charge engine will complete the job. Remove the controller to perform electrical diagnostics on other vehicles while the charging/ power supply functions are already in use. When the charging session is done, you can upload the session results wirelessly from the diagnostic charge engine to the controller for review or printing.
Maximum Service Flexibility Combines full EXP and GR8 functions with wireless multi-tasking to provide the maximum flexibility and efficiency. Allows the user to quickly and easily perform all battery and electrical diagnostics.
EXP Battery and Electrical Diagnostic Capability
Dynamic Conductance Battery Testing Technology
- Combines direct temperature measurement with deep scan technology to improve diagnostics
Advanced Electrical System Diagnostics Featuring Digital Signal Processing (DSP)
- Provides the ability to analyze the amplitude level and frequency of the ripple pattern for improved accuracy and identification of open or shorted diodes and open-phase conditions
DMM Functionality for Advanced Diagnostics
- AC/DC Volts, Volts/Amps mode, Temperature, Ohm meter, AC/DC Amps, Scope mode, Diode test
Patented Conductance Cable Drop Test
- Interactive test routine using dual cable sets for more effective analysis of voltage drop across ground circuit, starter system and alternator system, or more generic system testing
Models GR8-1200 AMP Includes EXP controller, GR8 Diagnostic Charger with built-in cart, Wireless Multi-tasker, (2) Serial Cables, Charging Cables, 10 Test Cables, Amp Clamp, Stud Adapters
GR8-1200 AMP KIT GR8-1200 with Integrated Printer
Accessories A141 Integrated Printer A018 Inductive Amp Clamp A028 DMM leads, 10 Cable Assembly with Clamps A126 DMM Adapter & Probe Kit A095 6-Pack Thermal Paper A129 Replacement Charger Cable Set A152 10 Replacement Battery/Starting/Charging System test cables
Applications 12 volt batteries 12+24 volt charging systems
Battery Test Leads 10 removable with Kelvin clamps
Charger Leads 6 removable Heavy Duty Kelvin Charge Clamps
Display 128 x 64 pixel graphics, backlit display
Battery Test Range For 12 volt batteries: 100-3000 CCA 100-1000 A (DIN) 100-3000 CA 100-3000 A (SAE) 100-3000 MCA 100-1000 A (IEC) JIS by Number 100-3000 A (EN)
Charging Voltage Up to 17 volts, 0.1V resolution (12 volt batteries)
Charging Current 0-60 amps, 1 amp resolution 80 amps peak 245 amps for cranking assistance (jump start)
Temperature Measurement EXP IR Sensor: -20 200 F Charger Clamp Sensor: -20 200F
Power Inputs: (charger) 110V, 60 Hz, 15-amp dedicated circuit
Operating Temperature 32 F 120 F (0 49 C)
Charger CUL Listed
Languages English French Canadian Spanish
Shipping Package 30 x 30 pallet 42 tall 110 lbs
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|