DCA-8000P Midtronics Dynamic Diagnostic Charging System, Conductance Profiling and Dynamic Charge Acceptance, Manual Charge Mode, Jump Start Mode, Reflash Mode, Includes Integrated Printer
Advanced diagnostic charging system featuring breakthrough core technology
Dynamic Charge Acceptance™ Combined with Conductance Profiling™, enables quick and accurate battery diagnosis, avoiding time wasted charging bad batteries. Mimics the start event with a large load, then applies a charge for a short period time. Performs critical diagnostics to verify battery can support start-stop applications
Conductance Profiling™ Combines our conductance algorithm with new proprietary technology. Identifies batteries with poor reserve capacity that may start the car, but could fail to support other vehicle accessories. Ensures service readiness for emerging vehicle systems, batteries, and new points of battery failure
How the DCA-8000 Evaluates TRUE BATTERY CONDITION The charge process is monitored throughout and discontinued immediately if at any point a battery is determined to be unrecoverable due to physical faults, etc. Most decisions are generated in 5 minutes or less.
Rapid decisions: Increases diagnostic speed generating most battery decisions in five minutes or less.
Greater accuracy: Comprehensive detection diagnostics assess a range of additional battery conditions - including charge acceptance, defect and degradation, cold battery, deep discharge, stratification, and internal battery temperature to deliver a comprehensive picture of battery condition.
Support for advanced vehicle systems: Assesses battery ability to support optimal operation of start-stop, regenerative braking, and variable output alternators; future technologies managed via regular software updates. As the complexity of battery and electrical systems continue to evolve, your diagnostic technology must be able to keep pace. New battery chemistries, types and construction. Advanced power management systems. Greater demand on batteries to support vehicle electronics and accessories
Self-diagnostics: Provides users with proactive tool performance warnings; such as cable degradation, internal component malfunction, etc. BMIS integration: BMIS is a cloud-based platform that supports battery service data storage, data sharing among BMIS-capable devices, equipment software updates, and flexible analytical and reporting options. Available as an optional subscription service. Customer communication: Email diagnostic results to customers, or print hard-copy results via optional integrated printer VIN capture options: Optional barcode scanner, optional CVG convergence module, integration with DSS-5000 Battery Diagnostic Service System, or manual entry Optional cart: Large back wheels, pivoting front wheels, and a full-width push handle improve mobility in the shop environment
Safety Features • Reverse polarity • Clamp connection • Non-12V battery connection • Battery voltage too low (< 5.5 V) • Clamp high temperature detection
BMIS-Enabled • Remote “over the air” software updates • Remote diagnostics • Enterprise asset management • Reporting and analytic tools • Communication with next generation Midtronics platforms and tools
User Interface • Advanced navigation and charge applications • Remote notifications (Wi-Fi- or Bluetooth-enabled) • Intuitive charge cycle feedback • 5” color touch-screen display
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Features
DCA-8000 Features
- 5" color touchscreen: More information and graphics on screen
- New Midtronics User Interface design: Consistent look and feel across all Midtronics equipment, minimizing training time
- Simple functional flow: Fewer screens & steps to reduce potential confusion points for the technician
- Dual temperature sensors: Improved temperature accuracy and cold battery detection
- Field-replaceable cables: In standard Sm or optional 5m lengths
- Wi-Fi capability: Supports charge data transmission and automatic over-the-air software updates
- Bluetooth 2.0 USB 2.0 connection
- Locking input/output cables: Reduce accidental disconnections
DCA-8000 Specifications
- Applications: Automotive, Power Sport, Marine
- Supported Battery Types: 6- and 12-volt batteries, Flooded Lead Acid,
AGM Spiral & Gel, Enhanced Flooded (EFB),12- and 24-volt charging
systems
- Diagnostic Technology: Dynamic Charge Acceptance,
Conductance Profiling, Enhanced Battery Temperature, Cold Battery
Diagnostic Charging.
- Communication: Wi-Fi communications & Bluetooth
- Input Voltage, 100 – 240VAC, 50/60Hz, 12A Max
- Output, 12V DC, 70A
Power
- Input: 100 – 240 , 50/60 Hz; 12A max.
- Output: 12 V , 70A
Charge Cables Power Cord
- Accepts C19 locking connector for region-specific power cables: United States: EMA 5-15 termination, rated at 15A/125V UL CSA
Applications
- Automotive
- Marine
- Heavy-Duty
- Group 31
- Power Sports
- Commercial 4D/8D
Battery Chemistries
- Lead acid
- EFB
- AGM
- Lithium ion
Rating System Operating Parameters
- Input Voltage: 100 – 240 , 50/60 Hz; 12A max.
- Output: 15VDC; 70A maximum
Humidity
- 15% to 85% R.H., non-condensing
Dimensions
- Height: 9.37" in (23.8 cm)
- Width: 17.25" in (43.81 cm)
- Depth: 17.82" in (45.26 cm)