TPI 712 Deluxe Combustion Efficiency Analyzer with Optional PC Interface - The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.
Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.
Determine combustion efficiency, CO2, and CO air free. Built-in differential manometer, combustible gas detection, PC communication, and data logging.
All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selectionduring start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need toperform fuel selection every time the analyzer is turned on.
The TPI 712 Flue Gas Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion. The instrument is ruggedly constructed and comes with a 3 Year unit and 2 Year sensor Guarantee.
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Features
- All the features of the 708 PLUS high resolution 0.001 in H20 differential manometer for high efficiency and oil equipment
- Measure CO, and temperature
- Calculate CO2, efficiency, excess air, and CO air free
TPI 709 Flue Gas Analyzer comes complete with the following standard accessories:
- TPI 709 Instrument
- Rubber Boot (A765)
- Soft Carrying Case (A768)
- Flue Sampling Probe (A770)
- In-Line Filter assembly installed on Flue probe (A794)
- Temperature Probe (GK11M)
- Mini Pump Protection Filter Assembly and spare filters (A763)
- Exhaust Spigot (removable) (A764)
- Instruction Manual
Model 712 Applications
- Tuning of residential and furnaces and domestic boilers
- Ambient and stack testing for CO
- CO safety measurements in and around combustion sources
- Temperature checking, including superheat and hydronic differential temperatures
- Detecting gas leak in gas lines and around gas fueled appliances. Dual input differential manometer with 3 selectable units of measure: kPa, mBar,inH20
Model 712 Specifications
|
Carbon Monoxide (CO)
Measurement
|
Range 0 to 10,000 ppm
Resolution 1 ppm
Accuracy +/-5ppm or 5% of reading whichever is greater
|
Oxygen (02) Measurement
|
Range 0 to 25%
Resolution 0.1%
Accuracy ±0.3%
|
Carbon Dioxide (CO2)
|
Range 0 to 25%
Resolution 0.1%
Calculated Value
|
Nitric Oxide Measurement
|
N/A
|
NOX Measurement
|
N/A
|
Temperature Measurement
|
Range -40 to 1472°F, or -40 to 800°C
Resolution 1°F or °C
Accuracy (K-type) ±0.3%, ±2°F or ±1°C
|
Draft/Pressure
Measurement
|
Selectable Ranges mBar,kPa, and inH2O
Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60
inH2O to +60 in H20
Resolution 0.001 inH2O
Accuracy ±0/5% fsd
|
Gross/Net Efficiency
|
Range 0 to 100%
Resolution 0.1%
Calculated Value
|
CO/CO2 Ratio
|
Range 0 to 0.999
Resolution 0.001
Calculated Value
|
Combustible Gas Level Indication
|
Yes (For flue gasses)
|
Operating Temperature
|
14°F to 122°F (-10°C to 50°C)
|
Battery Type
|
Rechargeable Batteries
|
Selectable Fuels
|
Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
Anthracite Coal, Coke, Butane, Wood, Bagasse
|
Display Type
|
Backlit 3 line LCD
|
Data Storage
|
50 Locations
|
Data Logging
|
Yes (5 Pages)
|
Print Capability
|
Yes, via optional IR printer (A740)
|
PC Communication
|
Yes via optional IR adapter (A767)
|
Date and Time Function
|
24 Hour Real Time Clock
|
Dimensions
|
200mm x 90mm x 60mm
|
Weight
|
500g
|
Conformity
|
BS7927 (and the draft BS7967)
|
|
|
|
|
|
|