AR2788S CPS R-134a Refrigerant Recovery Recycling Unit Parts
ITEM |
DESCRIPTION
|

|
39-020 |
6"
115 VOLT FAN |
54-100 |
OIL INJECTION BOTTLE |
AR2788SX1 |
AR2788S LOW BLOCK ASSY S/N PRIOR 10/12 27AR001801 |
AR2788SX10 |
AR2788S
BLUE LOWSIDE SERVICE HOSE S/N PRIOR 10/12
27AR001801 |
AR2788SX11 |
LIQUID
TANK TO FILTER IN HOSE ASSY |
AR2788SX12 |
AR2788S VAPOR TANK HOSE W/ BALL VALVE S/N PRIOR 10\12
27AR001801 |
AR2788SX13 |
AR2788S
DISCHARGE FILER HOSE W/ H ASSY S/N PRIOR 10\12
27AR001801 |
AR2788SX17 |
BLACK SCALE PATCH CORD |
AR2788SX18 |
RED
RELAY PCB PATCH CORD |
AR2788SX19 |
YELLOW LOW SIDE BLOCK PCB PATCH CORD |
AR2788SX2 |
AR2788S
HIGH BLOCK ASSY |
AR2788SX20 |
GREEN HIGH SIDE BLOCK PCB PATCH CORD |
AR2788SX21 |
AR2788S
LOW SIDE BLOCK PCB |
AR2788SX22 |
AR2788S HIGH SIDE BLOCK PCB |
AR2788SX23 |
AR2788S
MAIN PCB |
AR2788SX24 |
LCD PCB |
AR2788SX25 |
3
RELAY PCB S/N
PRIOR 10/12 27AR001801 |
AR2788SX26 |
TANK TEMP SENSOR OIL SEPARATOR S/N PRIOR 10/12 27AR001801 |
AR2788SX27 |
TEMPERATURE
SENSOR AMBIENT MAIN PCB S/N PRIOR 10/12
27AR001801 |
AR2788SX28 |
OIL INJECTION ASSY |
AR2788SX29 |
TANK
FILTER BRACKET/STRAPS |
AR2788SX3 |
SCALE MODULE |
AR2788SX30 |
OIL
DRAIN BOTTLE |
AR2788SX34 |
ON-OFF MOMENTARY SWITCH |
AR2788SX35 |
OIL
DRAIN TO BULK HEAD HOSE S/N BEYOND 10\12 27AR001802 |
AR2788SX36 |
FILTER OUT TO BULK HEAD LIQUID FITTING
HOSE S/N BEYOND
10/12 27AE001802 |
AR2788SX37 |
LS1
WITH BULK HEAD LIQUID FITTING HOSE S/N BEYOND 10/12
27AR001802 |
AR2788SX38 |
HV1 w/BULK HEAD VAPOR FITTING HOSE S/N BEYOND 10/12 27AR001802 |
AR2788SX39 |
COMPRESSOR
OIL SUMP TO HV3 HOSE S/N BEYOND 10/12
27AR001802 |
AR2788SX4 |
AR2788S/AR2700 COMPRESSOR ASSY 115V |
AR2788SX40 |
OIL SEPARATOR DRAIN-HV2 HOSE S/N BEYOND 10/12
27AR001802 |
AR2788SX41 |
HV2-COMPRESSOR S2 HOSE S/N BEYOND 10/12 27AR001802 |
AR2788SX42 |
COMP
DISCHARGE TO OIL SEPARATOR IN HOSE S/N BEYOND 10\12
27AR001802 |
AR2788SX7 |
REGULATOR SET 50 PSI |
AR2788SX9 |
AR2788S
RED HIGH SIDE SERVICE HOSE S/N PRIOR 10/12
27AR001801 |
AR2788X14A |
1/2 ACME REFILL HOSE |
AR2788X14B |
1/4
SAE REFILL HOSE |
AR2788X16 |
LOW SIDE GAUGE KIT |
AR2788X17 |
HIGH
SIDE GAUGE KIT |
AR2788X18 |
LOW SIDE CHARGE ADAPTER
|
AR2788X25 |
SCALE
PCB |
AR2788X28 |
POWER SUPPLY PCB |
AR2788X30 |
1
LB CHECK WEIGHT |
AR2788X32 |
15 AMP BREAKER 115 VAC |
AR2788X35 |
KEY
PAD |
AR2788X40 |
6 FT POWER CORD 115 VAC |
AR2788X45 |
HIGH
PRESSURE SWITCH 450PSI |
AR2788X46 |
PRESSURE TRANSDUCER |
AR2788X53 |
IEC
HEATER BLANKET/VAC PUMP OUTLET |
AR2788X57 |
1/8 GAUGE TUBE/WITH COMPRESSION FITTINGS |
AR2788X64 |
CASTOR
W/BRAKE |
AR2788X65 |
10" WHEEL |
AR27XHB115 |
115
VAC HEATER BLANKET |
AR27XHB115 |
115 VOLT 300 WATT HEATER BLANKET |
ARXF5 |
RECYCLING
FILTER |
CRX400T |
50 LB TANK |
CRX400T |
90
LB TANK |
FA1234X10 |
134A LOW SIDE SERVICE HOSE S/N BEYOND 10/12 27AR001802 |
FA1234X13 |
DISCHARGE
TO TANK VALVE HOSE VAPOR S/N BEYOND 10/12
27AR001802 |
FA1234X14 |
134A FILTER TO LIQUID H ASSY HOSE S/N BEYOND 10/12 27AR001802 |
FA1234X16 |
VAC
PUMP HOSE S/N
BEYOND 10/12 27AR001802 |
FA1234X28 |
4 RELAY
PCB S/N
BEYOND 10/12 27AR001802 |
FA1234X29 |
TEMP
SENSOR INTERNAL TANK VAPOR LINE S/N BEYOND 10/12
27AR001802 |
FA1234X30 |
TEMP SENSOR AMBIENT S/N BEYOND 10/12 27AR001802 |
FA1234X34 |
134A
COUPLER STORAGE FITTINGS SET S/N BEYOND 10/12 27AR001802 |
FA1234X39 |
IEC INLET, SCREW MOUNT |
FA1234X5 |
FA1234
OIL DRAIN BOTTLE ASSEMBLY S/N BEYOND 10/12
27AR001802 |
FA1234X6 |
LOW BLOCK COMPLETE S/N
BEYOND 10/12 27AR001802 |
FA1234X9 |
134A
HIGH SIDE SERVICE HOSE S/N BEYOND 10/12
27AR001802 |
QCH134 |
134A HIGH SIDE SERVICE COUPLER |
QCL134 |
134A
LOW SIDE SERVICE COUPLER |
VP6D |
VACUUM PUMP 6 CFM 2 STAGE |
VPXF15 |
VACUUM
PUMP FUSE |
VPXODP |
VACUUM PUMP OIL DRAIN PLUG |
VPXOMP |
VACUUM
PUMP EXHAUST CAP |
|
|
TROUBLESHOOTING |
Problem |
High
Pressure Limit. |
Solution |
Check that both Storage Tank valves are
open. Check that any inline hose ball valves to the Storage Tank are open. |
Problem |
Tank
Overfill. |
Solution |
Remove refrigerant from Storage Tank by
charging into an empty refrigerant cylinder. If this does not fix the
problem, then Re-Zero scale. |
Problem |
Unit not
Charging accurately. |
Solution |
Make sure Storage Tank is properly placed on
platform so that no portion of the tank is touching the back of the unit or
protective frame work of the unit. |
Solution |
Do not move
the unit while in the charging mode. The unit utilizes a weighing method of
charging. Sudden movement of the storage tank will affect the charging
accuracy. |
Solution |
Make sure unit is on a level surface. If
placed on surface with more than 2% grade, the charging amount may be
incorrect. |
Problem |
Unit will
not power up. |
Solution |
Check to make sure power switch on the back
of unit is ON. |
Solution |
Check to
make sure circuit breaker on back of unit is not tripped. Reset and restart
the unit if necessary. |
Solution |
Push the battery reset button on the back of
the unit. |
Solution |
Make sure
power cord is plugged into the back of the unit and the wall receptacle. |
Problem |
Upon compressor start up, the circuit
breaker trips. |
Solution |
Reset
circuit breaker and try again. |
Problem |
Upon vacuum pump start up, the circuit
breaker trips. |
Solution |
Check Oil
Level in vacuum pump. Reset circuit breaker and try again. |
Solution |
Make sure vacuum pump voltage switch is in
the correct position. |
|
|
|