Feature |
83V |
87V |
True-rms ac voltage and current for accurate measurements on non linear signals |
|
• |
Selectable filter for accurate voltage and frequency measurements on motor drives |
|
• |
0.05 % dc accuracy |
|
• |
6000 counts, 3-3/4 digits |
• |
• |
4-1/2 digit mode for precise measurements (20,000 counts) |
|
• |
Measure up to 1000 V ac and dc |
• |
• |
Measure up to 10 A, 20 A for up to 30 seconds |
• |
• |
Built in thermometer lets you carry one less tool (TC probe included) |
|
• |
Frequency to 200 kHz and % duty cycle |
• |
• |
Resistance, continuity and diode test |
• |
• |
10,000 µF capacitance range for components and motor caps |
• |
• |
Min/Max-Average recording with Min/Max Alert to capture variations automatically |
• |
• |
Peak capture to record transients as fast as 250 µs |
• |
• |
Relative mode to remove test lead interference from low ohms measurements |
• |
• |
Auto and manual ranging for maximum flexibility |
• |
• |
Touch Hold to capture stable readings avoiding noisy signals |
• |
• |
Large display digits and two-level bright white backlight for increased visibility |
• |
• |
Analog bargraph for fast changing or unstable signals |
• |
• |
Input Alert provides audible warning against wrong use of input jacks |
• |
• |
Improved selectable sleep mode for long battery life |
• |
• |
Access door for fast battery changes without breaking the calibration seal |
• |
• |
"Classic" design with new removable holster with built in test lead and probe storage |
• |
• |
Lifetime warranty |
• |
• |
Specifications |
Voltage DC |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 83 V: ±(0.1%+1) |
|
Fluke 87 V: ±(0.05%+1) |
Maximum Resolution: |
Fluke 83 V: 100 µV |
|
Fluke 87 V: 10 µV | |
Voltage AC |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 83 V: ±(0.5%+2) |
|
Fluke 87 V: ±(0.7%+2) True RMS |
AC Bandwidth |
Fluke 83 V: 5kHz |
|
Fluke 87 V: 20kHz* |
|
*with low pass filter; 3db @ 1kHz |
Maximum Resolution: |
0.1 mV | |
Current DC |
Maximum Amps: |
10A (20 A for 30 seconds maximum) |
Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
|
Fluke 87 V: ±(0.2%+2) |
Maximum Resolution: |
Fluke 83 V: 0.01 mA |
|
Fluke 87 V: 0.01 µA | |
Current AC |
Maximum Amps: |
10A (20 A for 30 seconds maximum) |
Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
|
Fluke 87 V: ±(1.0%+2) True RMS |
Maximum Resolution: |
0.1 µA | |
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
Fluke 83 V: ±(0.4%+1) |
|
Fluke 87 V: ±(0.2%+1) |
Maximum Resolution: |
0.1Ω | |
Capacitance |
Maximum Capacitance |
9,999 µF |
Accuracy |
±(1%+2) |
Maximum Resolution |
0.01 nF | |
Frequency |
Maximum Frequency |
200 kHz |
Accuracy |
±(0.005%+1) |
Maximum Resolution |
0.01 Hz | |
Duty Cycle |
Maximum Duty Cycle |
99.9% |
Accuracy |
±(0.2% per khz +0.1%) |
Maximum Resolution |
0.1% | |
Temperature Measurement |
Fluke 87 V, 87 V/E: |
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F |
|
excluding probe | |
80 BK Temperature Probe |
|
-40.0°C - 260°C |
|
-40.0°F - 500°F, 2.2°C or 2% whichever is greater | |
Conductance |
Maximum Conductance |
60.00 nS |
Accuracy |
±(1.0%+10) |
Maximum Resolution |
0.01 nS | |
Diode |
Range: |
3 V |
Resolution: |
1 mV |
Accuracy: |
± (2 % + 1) | |
Duty Cycle Range |
Accuracy: |
Within ± (0.2% per kHz + 0.1 %) | |
Environmental Specifications |
Operating Temperature |
|
Storage Temperature |
|
Humidity (Without Condensation) |
|
0% - 90% (0°C - 35°C) |
|
0% - 70% (35°C - 55°C) | |
Operating Altitude |
|
Safety Specifications |
Overvoltage category |
|
EN 61010-1 to 1000 V CAT III, 600V CAT IV | |
Agency Approvals |
|
Mechanical & General Specifications |
Size |
|
201 x 98 x 52 mm (with holster) | |
Weight |
|
Weigh With Holster and Flex-Stand |
|
Display |
Digital: |
6000 counts updates 4/sec. |
|
(Model 87 also has 19,999 counts in high-resolution mode.) |
Analog: |
32 segments, updates 40/sec. |
Frequency: |
19,999 counts, updates 3/sec at > 10 Hz. | |
Warranty |
|
Battery Life |
Alkaline: |
~400 hours typical, without backlight | |
Shock |
|
1 Meter drop per IEC 61010-1:2001 | |
Vibration |
|
Per MIL-PRF-28800 for a Class 2 instrument | |
|
|
|
|
|
|
|