Automotive tools & equipment

HVAC & Industrial supplies

Sales - parts -service


  Home > Diagnostic Tools >

87 V Fluke True RMS Multimeter With Temperature

87 V Fluke True RMS Multimeter With Temperature
 
Price $686.85


Product Code: FLK87-5
Qty:

Description Prop65
 

The new Fluke 87V has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.

The 80 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection. The new 80 series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
New features for maximum productivity
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
  • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
  • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
  • Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models
Product Features
  • Industrial True RMS Multimeter with Temperature
  • Measure up to 1000V AC and DC
  • Built-in thermometer conveniently allows to take temperature readings without having to carry a separate instrument
  • Withstands hazardous 8,000 volt spikes caused by load switching
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
  • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
  • Large digit display with bright, two-level backlight makes this model significantly easier to read than older models

Model Includes:

  • TL75 test leads
  • AC72 Alligator Clips
  • Holster
  • 9V battery (installed)
  • Getting Started Manual
  • CD with detailed manual
  • 80BK temperature probe
  • Feature
    83V
    87V
    True-rms ac voltage and current for accurate measurements on non linear signals
    Selectable filter for accurate voltage and frequency measurements on motor drives
    0.05 % dc accuracy
    6000 counts, 3-3/4 digits
    4-1/2 digit mode for precise measurements (20,000 counts)
    Measure up to 1000 V ac and dc
    Measure up to 10 A, 20 A for up to 30 seconds
    Built in thermometer lets you carry one less tool (TC probe included)
    Frequency to 200 kHz and % duty cycle
    Resistance, continuity and diode test
    10,000 µF capacitance range for components and motor caps
    Min/Max-Average recording with Min/Max Alert to capture variations automatically
    Peak capture to record transients as fast as 250 µs
    Relative mode to remove test lead interference from low ohms measurements
    Auto and manual ranging for maximum flexibility
    Touch Hold to capture stable readings avoiding noisy signals
    Large display digits and two-level bright white backlight for increased visibility
    Analog bargraph for fast changing or unstable signals
    Input Alert provides audible warning against wrong use of input jacks
    Improved selectable sleep mode for long battery life
    Access door for fast battery changes without breaking the calibration seal
    "Classic" design with new removable holster with built in test lead and probe storage
    Lifetime warranty

    Specifications
    Voltage DC
    Maximum Voltage: 1000V
    Accuracy: Fluke 83 V: ±(0.1%+1)
    Fluke 87 V: ±(0.05%+1)
    Maximum Resolution: Fluke 83 V: 100 µV
    Fluke 87 V: 10 µV
    Voltage AC
    Maximum Voltage: 1000V
    Accuracy: Fluke 83 V: ±(0.5%+2)
    Fluke 87 V: ±(0.7%+2) True RMS
    AC Bandwidth Fluke 83 V: 5kHz
    Fluke 87 V: 20kHz*
    *with low pass filter; 3db @ 1kHz
    Maximum Resolution: 0.1 mV
    Current DC
    Maximum Amps: 10A (20 A for 30 seconds maximum)
    Amps Accuracy: Fluke 83 V: ±(0.4%+2)
    Fluke 87 V: ±(0.2%+2)
    Maximum Resolution: Fluke 83 V: 0.01 mA
    Fluke 87 V: 0.01 µA
    Current AC
    Maximum Amps: 10A (20 A for 30 seconds maximum)
    Amps Accuracy: Fluke 83 V: ±(1.2%+2)
    Fluke 87 V: ±(1.0%+2) True RMS
    Maximum Resolution: 0.1 µA
    Resistance
    Maximum Resistance: 50 MΩ
    Accuracy: Fluke 83 V: ±(0.4%+1)
    Fluke 87 V: ±(0.2%+1)
    Maximum Resolution: 0.1Ω
    Capacitance
    Maximum Capacitance 9,999 µF
    Accuracy ±(1%+2)
    Maximum Resolution 0.01 nF
    Frequency
    Maximum Frequency 200 kHz
    Accuracy ±(0.005%+1)
    Maximum Resolution 0.01 Hz
    Duty Cycle
    Maximum Duty Cycle 99.9%
    Accuracy ±(0.2% per khz +0.1%)
    Maximum Resolution 0.1%
    Temperature Measurement
    Fluke 87 V, 87 V/E: -200.0°C - 1090°C
    -328.0°F - 1994.0°F
    excluding probe
    80 BK Temperature Probe
    -40.0°C - 260°C
    -40.0°F - 500°F, 2.2°C or 2% whichever is greater
    Conductance
    Maximum Conductance 60.00 nS
    Accuracy ±(1.0%+10)
    Maximum Resolution 0.01 nS
    Diode
    Range: 3 V
    Resolution: 1 mV
    Accuracy: ± (2 % + 1)
    Duty Cycle Range
    Accuracy: Within ± (0.2% per kHz + 0.1 %)

    Environmental Specifications
    Operating Temperature
    -20°C to +55°C
    Storage Temperature
    -40°C to +60°C
    Humidity (Without Condensation)
    0% - 90% (0°C - 35°C)
    0% - 70% (35°C - 55°C)
    Operating Altitude
    2000 m

    Safety Specifications
    Overvoltage category
    EN 61010-1 to 1000 V CAT III, 600V CAT IV
    Agency Approvals
    UL, CSA, TÜV, VDE listed

    Mechanical & General Specifications
    Size
    201 x 98 x 52 mm (with holster)
    Weight
    355 g
    Weigh With Holster and Flex-Stand
    624 g
    Display
    Digital: 6000 counts updates 4/sec.
    (Model 87 also has 19,999 counts in high-resolution mode.)
    Analog: 32 segments, updates 40/sec.
    Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
    Warranty
    Lifetime
    Battery Life
    Alkaline: ~400 hours typical, without backlight
    Shock
    1 Meter drop per IEC 61010-1:2001
    Vibration
    Per MIL-PRF-28800 for a Class 2 instrument