The Legend Series™ HFC Refrigerant Analyzer is the most precise portable instrument ever manufactured for field applications to determine the purity of gaseous refrigerants in the HVAC/R market. Clean air calibration is all you need to analyze your refrigerant in less than 2 minutes. No matter the application, Bacharach’s Legend Series™ HFC Refrigerant Analyzer is capable of measuring vapor or liquid refrigerant to confirm purity while detecting the presence of other harmful refrigerants or air.
Identify & Analyze With Confidence In the last few years, there has been an emergence of new refrigerants in the market to support the F-Gas phasedown regulations. These more environmentally friendly refrigerants are sold as replacements or retrofits for high Ozone Depleting (ODP) or high Global Warming Potential (GWP) refrigerants. These new refrigerants are often meant to replace these high ODP or GWP refrigerants in older systems, but it is often very hard to determine if a new gas was added to or used in place of another refrigerant. Too often these refrigerants are meant to function like their less environmentally friendly predecessors, which means pressure/temperate (P/T) curves are going to be very similar to keep systems running efficiently. This increases difficulty in confirming a refrigerant is as expected without the use of a refrigerant analyzer.
No longer are there only a few familiar refrigerants in the market. There are new blends being released all the time and there is no sure way to know what refrigerant you are working with if you don’t have a tool designed to analyze the gas. Simply assuming a refrigerant is right, or only relying on P/T charts, can cause more confusion and lead to mixing or inappropriate application use of refrigerants. Now more than ever it has become necessary to verify every refrigerant in a system or cylinder is correct to ensure that equipment runs effectively and efficiently. With the presence of only a small amount of air, a (P/T) analysis can fail and lead to costly service. Moreover, mixing refrigerants can lead to system failures and potentially put the user or unsuspecting service technician at risk of injury or harm.
The Legend Series™ HFC is the Answer! Confirming a refrigerant is the right gas before service or use will ensure all systems effectively operate while protecting the customer and the technician. The use of a refrigerant analyzer creates a cleaner recovery process and reduces the amount of mixed gas recovered. Reducing mix gas recovery will ultimately cut down on the amount of refrigerant that must be destroyed which helps improve the industry’s ecological footprint.
A refrigerant analyzer is a valuable tool to safeguard users and equipment, while promoting recycling and reuse to protect the environment. Bacharachs' Legend Series™ HFC is the most advanced refrigerant analyzer in the market and provides the latest in NDIR technology to support refrigerant testing before use. Reduce the uncertainty and analyze every refrigerant before handling so you can ensure you are safeguarding yourself, your equipment, and the environment to certify the job is done right.
Contamination of refrigerants either in storage cylinders or HVAC/R system can lead to component corrosion, elevated head pressures and system failures when utilized by unsuspecting technicians. The ability of the technician to determine refrigerant type and purity is severely hampered by the presence of air when attempting to utilize temperature-pressure relations. The development of various substitute refrigerants further complicates the ability of a technician to identify refrigerant purity based upon temperature-pressure relationships. The Bacharach Legend Series™ HFC Refrigerant Analyzer will provide a fast, easy and accurate means to determine refrigerant purity in refrigerant storage cylinders or directly in an HVAC/R system. The instrument utilizes non-dispersive infrared (NDIR) technology to determine the weight concentration of many common refrigerants. The instrument is supplied complete with a ¼” Flare Vapor Sampling Hose, ¼” Flare Liquid Sample Hose, Hose Extensions for ease of connection, a High-Pressure Liquid Sample Trap Assembly, a 100-240 VAC power transformer, built in rechargeable Lithium-Ion battery, thermal printer, and all required plumbing housed within a rugged, portable, storage case. Sample gas is admitted into the instrument through the supplied sample hose and presented to the sensing device. The instrument provides the user with a digital display of refrigerant purity or identified refrigerant. The instrument only considers the weights of the refrigerant and contaminates in the total mixture. Air is measured, and displayed, separately. Other contents such as refrigerant oil, moisture and dye are not considered contaminants. The instrument interfaces with the user via a full color graphic LCD, audio indications and soft key command buttons. Alarm indications are provided to alert of instrument fault conditions or contaminated refrigerant presence.
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Features
- Quickly and accurately determines refrigerant purity
- Advanced ergonomic design
- Analyzes percentage purity
- Identifies specific refrigerants
- Displays percentage AIR independent of the refrigerant sampled
- Multiple Languages: English, German, Spanish, French, Italian, Portuguese, Chinese, Japanese, Korean and Russian
- Vapor or Liquid Sampling
- Easily prints test results with built-in printer
- Uses Standard 2.25” (57 mm) thermal paper
- Improved oil resistance with user replaceable hose assembly
- Full Color Graphic LCD with on-screen instructions
- Ultra-fast test time
- Internal, rechargeable Lithium-Ion battery for cordless operation in any location
- USB Port for test data storage and software updates (USB Drive not included)
- All accessories stored in hard shell carry/storage case
Includes:
- Built-in printer
- Separate ¼” Flare Sample Hoses For Vapor And Liquid
- AC Power Supply
- Internal LiFe Battery
- All Required Plumbing
-
Housed In A Rugged, Portable Storage Case
Specifications Measuring Range: 0-100% Accuracy: +/-2% of single component refrigerants User Interface: Graphic Display, Soft Keys, Built in Printer Display Size: 5" Color LCD Power: 12 VDC @ 2A via 110/220 VAC, 50 - 60Hz Adapter, Built in Lithium-Ion Battery Ambient Temperature: 50 to 120°F (10 to 49°C) Humidity: 0-95% RH non-condensing Pressure: Adequate 30-500 psig (2 – 34 Bar), Pressures < 30 psig (2 bar) allow added flow time Altitude: 0 to 8,000' (2,440 m) Product Weight: Less than 10 lbs. Approvals: CE, UL, and CUL Warranty: 1 Year Sample Type: Vapor, Liquid Sample Parameters: Vapor or Liquid depending on hose configuration, oil-free (displays % purity): R-22, R-32, R-134a, R-404A, R-407C, R-410A, Hydrocarbons (HC) and Air Identified Refrigerants (NO % purity): R-12, R-1234yf, R-408A, R-409A, R-417A, R-421A, R-421B, R-422A, R-422B, R-422C, R-427A Printer: Integrated Thermal Printer Refrigerant % Displayed: R-22, R-32, R-134a, R-404A, R-407C, R-410A, Hydrocarbons (HC) and Air Test Time: 120 seconds Country of Origin: United States