TPI 708A740 Combines the 708 Combustion Efficiency Analyzer with the A740 Infrared Printer - TPI Model 708 Combustion Efficiency Analyzer. The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.
Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.
Determine combustion efficiency, CO2, and CO air free. Some models include built-in differential manometer, combustible gas detection, PC communication, data logging, and can measure NO / NOX.
All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selectionduring start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need toperform fuel selection every time the analyzer is turned on.
Using TPI analyzers to determine combustion efficiency at the time of equipment set up minimizes call backs and can be used to verify to the home owner the value of service work by showing the increase in equipment efficiency after work is performed. Efficiency calculation can also be used to generate business by demonstrating the need to improve the efficiency of equipment or to show the benefit of purchasing new equipment with higher efficiency.
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Features
- Measure CO, and temperature
- Calculate CO2, efficiency, excess air, and CO air free
- Calculates combustion efficiency
- Pump driven for fast response
- Will not shut off if 15 ppm CO is present for increased safety
- Ten selectable fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
- Optional A740 IR printer available for hard copies of test results
- Built-in differential thermometer
- Store function to save up to 50 readings
- Large easy to read backlit display
TPI 708 Flue Gas Analyzer comes complete with the following standard accessories:
- TPI 708 Instrument
- Rubber Boot (A765)
- Soft Carrying Case (A768)
- Flue Sampling Probe (A770)
- In-Line Filter assembly installed on Flue probe (A794)
- Temperature Probe (GK11M)
- Mini Pump Protection Filter Assembly and spare filters (A763)
- Exhaust Spigot (removable) (A764)
- Instruction Manual
Model 708 Applications:
- Tuning of residential and furnaces and domestic boilers
- Ambient and stack testing for CO
- CO safety measurements in and around combustion sources
- Temperature checking, including superheat and hydronic differential temperatures
Model 708 Specifications
|
Carbon Monoxide (CO)
Measurement
|
Range 0 to 10,000 ppm
Resolution 1 ppm
Accuracy +/-5ppm or 5% of reading whichever is greater
|
Oxygen (02) Measurement
|
Range 0 to 25%
Resolution 0.1%
Accuracy ±0.3%
|
Carbon Dioxide (CO2)
|
Range 0 to 25%
Resolution 0.1%
Calculated Value
|
Nitric Oxide Measurement
|
N/A
|
NOX Measurement
|
N/A
|
Temperature Measurement
|
Range -40 to 1472°F, or -40 to 800°C
Resolution 1°F or °C
Accuracy (K-type) ±0.3%, ±2°F or ±1°C
|
Draft/Pressure
Measurement
|
Selectable Ranges mBar,kPa, and inH2O
Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60
inH2O to +60 in H20
Resolution 0.001 inH2O
Accuracy ±0/5% fsd
|
Gross/Net Efficiency
|
Range 0 to 100%
Resolution 0.1%
Calculated Value
|
CO/CO2 Ratio
|
Range 0 to 0.999
Resolution 0.001
Calculated Value
|
Operating Temperature
|
14°F to 122°F (-10°C to 50°C)
|
Battery Type
|
1.5V AA (3)
|
Selectable Fuels
|
Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
Anthracite Coal, Coke, Butane, Wood, Bagasse
|
Display Type
|
Backlit 3 line LCD
|
Data Storage
|
50 Locations
|
Data Logging
|
N/A
|
Print Capability
|
Yes, via optional IR printer (A740)
|
PC Communication
|
N/A
|
Date and Time Function
|
24 Hour Real Time Clock
|
Dimensions
|
200mm x 90mm x 60mm
|
Weight
|
500g
|
Conformity
|
BS7927 (and the draft BS7967)
|
A740 Features
- Power On indication (red LED)
- Adjustable contrast (low, norm, high)
- Manual paper feed (advance)
- Operates on 4 “AA” batteries or optional AC adapter
- Self test at Power On
- 3-Year Warranty
A740 Specifications:
- Maximum Transmitting Distance: 18 inches (45cm)
- Maximum Horizontal Receiving Angle: ±30°
- Verticle Receiving Angle: -10° to +20°
- Battery Power: 4 x 1.5V Alkaline Batteries
- Adapter: DC 9V / 1A, 60Hz, 120V (CUL) / (DC 7V / 1500mA, 50Hz, 240V [CE])
- Paper: A746
- Operating Temperature: 32°F to 122°F (0°C to 50°C)
- Operating Humidity:L 5% to 80% Relative Humidity
- Storage Temperature: 14°F to 140°F (-10°C to 60°C)
|
|
|
|
|
|