118039 Robinair Refrigerant Pressure Temperature Chart
Refrigerant Pressure Temperature Chart For 41600 Series Manifolds or Universal Application. Lists 12 refrigerants including R-12, R-22, R-134A, R-410A, R-502, R-401A, R-401B, R-402A, R-402B, R-404A Fits conveniantly on the rear of 41400, 41600, 40100 series gauges with protector.
Discontinued
360-80128-00 Mahle DOT Cylinder 30 Lb. 1/4 Flare
360-80128-00 Mahle DOT Cylinder 30 Lb. 1/4 Flare is a standard “re-usable” DOT container for R12. Its is rated for the extra high pressures of R22. Has 1/4 in. SAE connections. This unit does not have overfill protection.
360-80301-00 Mahle DOT Cylinder 30 Lb. R134a 1/2" ACME
The 360-80301-00 Mahle DOT Cylinder 30 Lb. R134a 1/2" ACME is a standard “re-usable” DOT container for R134a. Has 1/2 in. ACME connections. This unit DOES NOT HAVE OVERFILL PROTECTION - an Electronic Weight Scale is recommended as additional accessory to avoid over-filling or a float can be purchased and installed.
360-80332-00 Mahle DOT Cylinder 30 Lb. R134a 1/2 ACME With Float
The 360-80332-00 Mahle DOT Cylinder 30 Lb. R134a 1/2 ACME With Float is a standard "re-usable" DOT container for R34a with 1/2 in. ACME connections. This unit features an over-fill protection float switch. Compatible with RTI / Mahle equipment or others that use a Brad Harrison type electrical connector.
62010 Mastercool 30 lb D.O.T. Supply Tank R12
Mastercool 30 lb D.O.T. Approved Recovery Cylinders feature powder coated high gloss durable finish, y-valve for liquid / vapor, 3/4" NPT opening accepts 80% fill float switch shut-off device, 1/4" opening for air purge valve, easy to handle collar, conforms to DOT-4BA400 and ARI guidelines, pre-charged for a clean dry interior, store and transport recovered refrigerant, valve and float switch are UL listed, AUS and TC Canadian approved.
62011 Mastercool 30 lb D.O.T. Supply Tank W/ Float R12
Mastercool 30 lb D.O.T. Approved Recovery Cylinders feature powder coated high gloss durable finish, y-valve for liquid / vapor, 3/4" NPT opening accepts 80% fill float switch shut-off device, 1/4" opening for air purge valve, easy to handle collar, conforms to DOT-4BA400 and ARI guidelines, pre-charged for a clean dry interior, store and transport recovered refrigerant, valve and float switch are UL listed, AUS and TC Canadian approved.
64010 Mastercool 30 Lb. D.O.T. Supply Tank (R134A)
Mastercool 30 lb D.O.T. Approved Recovery Cylinders feature powder
coated high gloss durable finish, y-valve for liquid / vapor, 3/4" NPT
opening accepts 80% fill float switch shut-off device, 1/4" opening for
air purge valve, easy to handle collar, conforms to DOT-4BA400 and ARI
guidelines, pre-charged with nitrogen for a clean dry interior, store
and transport recovered refrigerant, valve and float switch are UL
listed, AUS and TC Canadian approved.
67010 Mastercool 30 Lb. D.O.T. Tank W/Float R134A (Blue)
Mastercool 30 lb D.O.T. Approved Recovery Cylinders feature powder
coated high gloss durable finish, y-valve for liquid / vapor, installed
80% fill float switch shut-off device, 1/4" opening for air purge valve,
easy to handle collar, conforms to DOT-4BA400 and ARI guidelines,
pre-charged with nitrogen for a clean dry interior, store and transport
recovered refrigerant, valve and float switch are UL listed, AUS and TC
Canadian approved.
74-099 CPS Magnetic Tank Thermometer 26?F To 120F? (-3?C To 49?C)
74-099 CPS Magnetic Tank Thermometer. 48 Point Temp Label Magnet, 26°F To 120F° (-3°C To 49°C). These magnetic temperature labels provide a safe, accurate, easy-to-read means for monitoring temperatures. Indicating strips use liquid crystal technology to display the current temperature at an economical cost. The strip will turn green when ambient temperature is reached. Great for tank temperature monitoring during recovery processes or air purge procedures.