Product Features
- High Resolution and unique back-light indicator make precision readings easy
- Patent Pending design, employs a sophisticated MEMS Pirani sensor
- Range from Atmosphere down to 10 microns
- Measure vacuum in Microns, mm-Hg, in-Hg, m-Bar, Pascals or Torr
- Extremely accurate at low micron levels
- Impact and water resistant case with protective Rubber boot
- Rapid response to changes in vacuum
- Large easy to read 5 digit display
- Auto shut off feature prolongs battery life
- Battery powered
- Integrated “magnetic” hook
- 1/8"-27 NPT Male Connection (1/8" MPT), Bottom Tap
- Includes carrying case and tee adapters or in-line connections (1/4" MFL x 1/4" MFL and 1/4" FFL x 1/4" MFL versions)
Includes: Tee fittings for
connection to system - 1/4" MFL x 1/4" MFL x 1/8" Female Pipe Branch and
1/4" FFL Swivel x 1/8" Female Pipe x 1/4" Male Flare Branch allowing for either in-line
hook-up or directly onto a vacuum pump or manifold.
(see photo above)
RAVG-1 Specifications
|
|
Operating Range
|
Atmosphere to 10 Microns
|
Resolution
|
As low as 5 Microns /
0.005 mmHg / 0.002 inHg / 0.007 mBar / 0.66 Pa / 0.005 Torr
|
Accuracy
|
As low as +/- 5 % of Reading
|
Over
pressure
|
450 psi / ~ 31 Bar
|
Measuring Units
|
Microns/mmHg/inHg/mBar/Pa/Torr
|
Display
|
5 digit STN LCD, 50 x 30
mm with tricolor LED backlight
|
Power Supply
|
3 x size “AAA”
Input 1,5 V Batteries
|
Connection
|
1/8"-27 NPT Male
(1/8" MPT)
|
|
|
|
|
|
|
|