Specifications |
Maximum voltage between any terminal and earth ground |
|
Surge protection |
|
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 | |
Display |
Digital: |
6,000 counts, updates 4 per second | |
Bar graph |
|
33 segments, updates 32 per second | |
Operating Temperature |
|
Storage Temperature |
|
Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
Battery Life |
|
400 hours typical, without backlight | |
Accuracy Specifications |
DC millivolts |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.00 V / 0.1 V |
Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts1 true-rms |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) | |
AC volts1 true-rms |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.0 V / 0.1 V |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) | |
Continuity |
Range: |
600 Ω |
Resolution: |
1 Ω |
Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. | |
Ohms |
Range/Resolution: |
600.0 Ω / 0.1 Ω |
Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
Accuracy: |
0.9 % + 1 |
Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
Accuracy: |
5 % + 2 | |
Diode Test |
Range/Resolution: |
2.00 V / 0.001 V |
Accuracy: |
0.9% + 2 | |
Capacitance |
Range/Resolution: |
1000 nF / 1 nF |
Range/Resolution: |
10.00 µF / 0.01 µF |
Range/Resolution: |
100.0 µF / 0.1 µF |
Range/Resolution: |
9999 µF / 1 µF |
Range/Resolution: |
100 µF to 1000 µF |
Accuracy: |
1.9% + 2 |
Range/Resolution: |
> 1000 µF |
Accuracy: |
5% + 20% | |
Lo-Z Capacitance |
Range: |
1 nF to 500 µF |
Accuracy: |
10% + 2 typical | |
AC amps true-rms (45 Hz to 500Hz) |
Range/Resolution: |
6.000 A / 0.001 A |
Range/Resolution: |
10.00 A / 0.01 A |
Accuracy: |
1.5% + 3 |
|
20 A overload for 30-seconds max | |
DC amps |
Range/Resolution: |
6.000 A / 0.001 A |
Range/Resolution: |
10.00 A / 0.01 A |
Accuracy: |
1.0% + 3 |
|
20 A overload for 30-seconds max | |
Hz (V or A input)2 |
Range/Resolution: |
99.99 Hz / 0.01 Hz |
Range/Resolution: |
999.9 Hz / 0.01 Hz |
Range/Resolution: |
9.999 kHz / 0.001 kHz |
Range/Resolution: |
50 kHz / 0.01 kHz |
Accuracy: |
0.1% + 2 | |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range.
Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications |
Size |
|
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") | |
Weight |
|
Warranty |
|